3.1.1  Prohibit discarding modules randomly, 

special recycling is needed

3.1.2  Protect modules from rain or moisture

3.1.3  Modules in carton are fragile, 

shall be handled with care

3.1.4  The package should be vertically up 

during transportation

3.1.5  Do not step on or stand above 

package or module

3.1 Marks on Outer Packaging

5

Jolywood (Taizhou) Solar Technology Co.,Ltd.

Kaiyang Rd., Jiangyan Economic Development zone, Taizhou City, Jiangsu Province, P. R. China

www.jolywood.cn

 mkt@jolywood.cn

 +86-523-8061 2361

        Always work under a dry environment, 
ensure that all modules and electrical contacts 
are clean and dry before installation. If it is 
necessary to store the modules outdoors for a 
certain period of time, always cover module 
and ensure that the glass surface is facing 
down on a soft surface, preventing water from 
entering inside of the module, preventing 
connectors from be damaged. Unpacking must 
be operated by two or more people at the same 
time. Do not lift module by grasping module 
terminal box or lead wires. Use both hands to 
carry the module and do not stack modules. 
Do not place modules in an environment without 
reliable support or unfixed. Do not place any 
heavy objects or sharp objects on modules.

the modules according to the recommended 
shipping method and unpacking procedure. 
Avoid damaging modules, scratching or striking 
the modules. Do not apply pressure directly on the 
unit during transportation. Improper transportation 
or installation may damage the modules, which 
excluded from the warranty. Do not stand, climb, 
walk or jump on unpacked pallets of modules.

Installation Manual

 - Jolywood N-type Mono-crystalline Double Glass Module

Summary of Contents for JW-HD108N

Page 1: ...INSTALLATION MANUAL Jolywood N type Mono crystalline Double Glass Module M10 Double glass module HD108N P All rights reserved Jolywood Taizhou Solar Technology Co Ltd...

Page 2: ...Installation Safety Mechanical installation and precautions Framed Bifacial Double Glass Modules installation with clamps Grounding Electrical installation Wiring Fuse Maintenance for PV Modules Modu...

Page 3: ...must be installed and maintained by quali ed person with professional knowledge Before installing wiring operating or maintaining modules you should read and understand all safety rules Modules will g...

Page 4: ...odules from be damaged please avoid scratching cutting the cables and connectors or exposed under the sun for a long time Do not drop module or drop other things onto the module surface Do not place a...

Page 5: ...le and ensure that the glass surface is facing down on a soft surface preventing water from entering inside of the module preventing connectors from be damaged Unpacking must be operated by two or mor...

Page 6: ...aged with original package could be transported by land sea or air During transportation xing the package to the transport platform to ensure it would not be tumbled Taking land transportation as an e...

Page 7: ...ng the corner of the module the other hand grasping the short side of the module When unpacking on a horizontal oor remove modules from one side to the other side of package and then carry them If unp...

Page 8: ...ic shock may be caused Modules should be installed immediately after unpacked 5 1 4 Do not wear metal rings wristwatches earrings nose rings lip rings or other metal materials when installing or repai...

Page 9: ...s y ste m d e s i g n e r b a s e d o n a c t u a l c o n d i t i o n s a n d en v i r o n m e n t a l M o r e o v e r i t d o e s n o t withstand the excessive force generated by the thermal expansi...

Page 10: ...d front 1200pa back 1200pa Mounted with 4 clamps along the short frame A 250mm 30mm C shaped steel parallel to the long frame Clamp height 30mm width 40 50mm Maximum load front 4800pa back 1200pa Moun...

Page 11: ...M8 A2 70 a stainless steel SUS304 at washer with an outer diameter of 20 2 mm and a thickness of 1 1 1 2 mm the corresponding stainless steel spring washer thickness is 2 0 0 2mm Bolt 11 Jolywood Tai...

Page 12: ...p e r ca b l e w i t h a c ro s s sectional area of 4mm2 system voltage 1500V DC insulation layer maximum work temperature up to 90 C also UV resistant All cables used to connect the DC system m u s...

Page 13: ...oads such as inverters batteries etc ensure that the polarity of the cables is properly connected Figure 1 and Figure 2 If modules are not connected properly the bypass diode may be damaged Modules co...

Page 14: ...ypass diodes to minimize module heating and current loss 6 1 2 Check if the installed hardware is securely in place 6 1 3 Check if all array fuses in each of the non grounded poles are working properl...

Page 15: ...essure on the surface of module glass shall not exceed 700 kPa 14619 80 lb ft2 and the module is not allowed to withstand additional external force such as oil on the surface of modules use a non fric...

Page 16: ...t http www jolywood cn Our technical service representatives will contact you within 5 working days The required username and password will be sent via the Customer Service link Please download the sp...

Reviews: