background image

SET-UP AND OPERATION: 

1. Before each use, inspect the machine, hoses, 

and cleaning tool for cleanliness and 
completeness, Ensure the spray nozzles on 
the cleaning tool are tight and that the ball 
float in the recovery tank is clean and 
operational. 
 

2. Close the clear, screw-on lid on the recovery 

tank, and screw the cap onto the drain hose. 
 

3. Fill the holding tank with clear water. 

 

NOTE: the heater on this machine is designed to 
provide nearly instant hot water for cleaning; if 
you use warm water in the solution tank it would 
increase heater proficiency. Never use water 
above 120

F or 49

C in the solution tank. 

 

4. Turn off all the switches. Plug the power cords 

into properly grounded outlets.  Do not 
connect both cords to the same outlet. 
 

5. Connect priming hose (included) to outlet QD 

 

6. Turn the pump ON and let water flow through 

priming hose until it is a clear flow, no air 
bubbles visible. 
 

7. Turn off pump switch, disconnect priming 

hose. Connect solution and vacuum hose to 
machine and tool 
 

8. Turn the heat switch ON and wait two 

minutes for the heater to reach operating 
temperature. 

 

 

NOTE: If you choose to add a detergent to the 
solution tank, be sure to mix well, and always 
follow the use & dilution instructions on the 
chemical label. Use a chemical with a pH between 
5 and 10 to reduce the likelihood of premature 
wear to the pump and other seals. 
 
9. Spray through your cleaning tool as you adjust 

the pressure regulator knob, on the front of 
the machine, to achieve the desired spraying 
pressure. 

 

9. Turn on the vacuum. 

 

10. Begin cleaning, following industry accepted 

practices. 
 

NOTE: Use defoamer any time foaming occurs in 
the recovery tank to prevent damage to the motor 
or other components. 
 
NOTE: Foam will not lift the ball float. 
 
12. Monitor the water level in the solution tank. 

Do not let the pump run dry. 
 

13. When the solution tank gets low, turn off the 

pump and vacuum, fill the solution tank, 
empty and clean the recovery tank.  

 
14.  When finished with the job, remove any 

unused solution from the solution tank, and 
run a few gallons of clean water through the 
system. Drain the recovery tank by opening 
the drain hose over a drain or a bucket. 
Release any residual pressure from the 
cleaning tool before disconnecting the hoses 
from the cleaning tool. 

AUTO VACUUM SHUT OFF: 

When the recovery tank is full, the ball float will 
shut off the suction to prevent the machine from 
overflowing. NOTE: The float may not work if 
there is too much foam in the tank. Always use 
defoamer to prevent overflow. 

HEAT SYSTEM: 

The heater holds a small amount of water, so to 
maintain hot water for the entire cleaning job, 
spray for short periods and then stop spraying 
during a recovery stroke. Continuous spraying 
will prevent the water from pausing long enough 
in the heater to get hot. 

Summary of Contents for Prospector PE5003

Page 1: ...Prospector PE5003 INFORMATION OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE Priority Manufacturing...

Page 2: ...Operating Instructions 6 Your New Machine 4 Warranty 7 System Features 4 Troubleshooting 8 Chemicals 4 Parts List 9 Tools Accessories 4 Exploded View 10 Machine Specifications Machine and Purchase Sp...

Page 3: ...o rain or snow and keep from extremes in temperature Store in a heated location Use the machine indoors Do not use outdoors Do not use this machine to dry vacuum before wet cleaning Do not use with da...

Page 4: ...to prevent overflow which can cause water damage to machine components The use of clear water in the machine is recommended within the application of properly diluted cleaner as a pre spray on the ar...

Page 5: ...Solution Tank Fill Hole VIEWS OF THE MACHINE FRONT VIEW Connect Solution Hose Here Pump Heat Switch Vacuum 2 Switch Vacuum 1 Switch 4 REAR VIEW Latches Power Cord Pigtails Switches Wand Holder Loadin...

Page 6: ...duce the likelihood of premature wear to the pump and other seals 9 Spray through your cleaning tool as you adjust the pressure regulator knob on the front of the machine to achieve the desired sprayi...

Page 7: ...ged or damaged solution hose or quick disconnect Pump not running No power to pump no power to cord AC to DC bridge rectifier is damaged On off switch is bad Pump motor is getting power but won t run...

Page 8: ......

Page 9: ...1 Lid Solution Tank 32 52 00006 2 Wheel 12 11 40 00400 2 Switch Vacuum Selector 33 41 00060 1 Axle 12 05 20002 FP0200 1 Switch Plate 34 32 00002 2 Axle Cap 13 41 00069 1 Filter Pump Inlet 35 42 00031...

Page 10: ...parts shipping of the new part and labor Manufacturer will ship parts via normal ground delivery prior to the return of the defective parts at normal charge to the Distributor Extra charges for expedi...

Reviews: