The registers with variables are the following:
The device is controllable and monitorable by using the only serial line.
N°
VARIABLE DEFINITION
UNITY
NOTES
TYPE
0
Firmware code
-
-
Lecture
1
Firmware version
-
-
Lecture
2
Modbus destination
-
-
Lecture / Scripture
3
Selected configuration
-
0: 2 short size generators
1: 2 long size generators
2: 4 short size generators
3: 4 long size generators
4: 1 short size generators
Lecture
4
ND
-
-
Lecture
5
ND
-
-
Lecture
6
Current generators voltage
cV
-
Lecture
7
Threshold MIN voltage
cV
-
Lecture
8
Alarm MIN voltage generators
-
0: not active
1: active
(type 0 to reset)
Lecture / Scripture
9
Threshold MAX voltage generators
cV
-
Lecture
10
Alarm MAX voltage generators
-
0: not active
1: active
(type 0 to reset)
Lecture / Scripture
11
Count hours maintenance
Hours
Hours
Lecture
12
Threshold count hours alarm
maintenance
Hours
If 0 the control is not
active
Lecture / Scripture
13
Alarm count hours
maintenance
-
0: not active
1: active
(type 0 to reset)
Lecture / Scripture
14
Count hours replacement
Hours
Hours
Lecture
15
Threshold count hours alarm
replacement
Hours
If 0 the control is not
active
Lecture / Scripture
16
Count hours alarm
maintenance
-
0: not active
1: active
(type 0 to reset)
Lecture / Scripture
17
Pilotage rating Modbus
On/Off
-
0: not enabled
1: enabled
-
18
Pilotage Modbus On/Off
-
0: not active ionisation
1: active ionisation
-
19
Manual threshold for MAX voltage
alarm generators
cV
-
Lecture / Scripture