User and Service manual JO960
Ver. 2.0
Ver. 1.1
7
Starting and working with JO960
Start the induction heater
1.
Make sure that nothing obstructs the airflow through the sides of
JO960.
2.
Turn the main switch to position 1.
“Reset” will be illuminated on the front panel.
3.
Press the “’Start/Reset switch”
“Reset” will go out and the “Start/Reset
switch” will be illuminated.
Work with JO960
4.
Place the heating tip on the work piece and press the On/Off
switch on the hand held transformer.
5.
Move the heating tip over the work piece that is to be heated.
Remark: Do not press the heating tip hard against the work piece.
It only wears the heating tip unnecessarily.
No higher effect will be reached through pressing the heating tip
against the work piece. It is quite sufficient to put the heating tip
against the work piece
6.
Release the on/off switch when the work piece has reached the
correct temperature. ( See e.g. JOSAM’s colour scale, T43 1-2-3
9712), and the heating tip stops heating.
Handling instructions for JO960
JO960 is divided into two main parts. The top (painted red) contains all
control and power electronics. Transformer cable equipped with a control
unit and a heating tip is connected to this upper part.
The lower part (painted silver) contains the cooling unit and water tank
Cooling unit
The working piece and the heating tip distribute much heat, water is used
as cooling agent. The water is cooled by a compressor with a condensor
(cooling unit). The cooling system is controlled automatically.
0