8
© Josef Kihlberg AB 2007
Troubleshooting
Always disconnect the tool from the air supply, empty the
magazine and read the
Safety precautions
section before
you begin troubleshooting.
To remove a staple which may have got stuck:
a, Push the magazine trigger to release the catch and pull
the inner rails all the way out.
b, Remove any staple remnants inside the magazine and
push the inner rail in until it clicks in behind the catch.
All safety devices must be inspected daily to ensure that
they are working properly. Make especially sure that:
the trigger moves freely without binding or sticking;
all screws and nuts are securely tightened.
This tool does not require special servicing. It only needs
regular cleaning with a non-aggressive cleaning agent. Do
not remove any parts for cleaning purposes.
Apply a small amount of lubricating oil to the nipple of the
tool every day or approximately 10 drops once a week to
maximize the life and utility of the tool. For high-frequency
stapling, we recommend oil-mist lubrication. Please contact
our agent for advice. Oil recommendation.
Part no.:
1 litre
184314
0.2 litre
733007
Sliding parts have been lubricated with Dow Corning MS
4 Silicon Compound at the factory. We recommend using
multipurpose grease on moving parts after they have been
cleaned or replaced.
•
•
Maintenance
EN
Summary of Contents for 126366
Page 1: ...operating instruction Josef Kihlberg AB 2007 EN DE FR SE JK10 680 126366 ...
Page 13: ...13 Josef Kihlberg AB 2007 Applications EN Optimising your stapling ...
Page 27: ...13 Josef Kihlberg AB 2007 Anwendungsbereiche DE Optimieren der Klammereinbringung ...
Page 41: ...13 Josef Kihlberg AB 2007 Applications FR Pour optimiser vos opérations d agrafage ...
Page 55: ...13 Josef Kihlberg AB 2007 Applikationer SE För att optimera din klamring ...
Page 58: ... Josef Kihlberg AB 2007 ...
Page 59: ... Josef Kihlberg AB 2007 ...