6
Installation
LubeTronic/211
E
1
LTXXXXXXXXXXXXXX
29
1
Software version
Pro-
gram
no.
Up to software version
xxx29
From software version
xxx30
1
Lubricating pulse 30 min. after
“ignition on”, then every 30 min.
2
Lubricating pulse 60 min. after
“ignition on”, then every 60 min.
3
Lubricating pulse 90 min. after
“ignition on”, then every 90 min.
4
Lubricating pulse 120 min. after “ignition
on”, then every 120 min. (
factory setting
)
5
Lubricating pulse 150 min. after
“ignition on”, then every 150 min.
6
Not used
Lubricating pulse imme-
diately after “ignition
on”, then every 15 min.
7
Not used
Lubricating pulse imme-
diately after “ignition
on”, then every 30 min.
8
Not used
Lubricating pulse imme-
diately after “ignition
on”, then every 60 min.
9
Not used
Lubricating pulse imme-
diately after “ignition
on”, then every 90 min.
10
Not used
Lubricating pulse imme-
diately after “ignition
on”, then every 120 min.
EN
LubeTronic
5Point
MUB 002 009 M01
(REV-B)
07-2020
13