background image

     

 

 

 

Dreyer Strasse 6-8  

Tel. +049 4203 

– 4400-0 

E-Mail

info@jotbe.com

                        

28844 Weyhe b. Bremen  

Fax +049 4203 

– 440010 

Internet

www.jotbe.com

                              1

 

 
 
Preface to operation manual: 

 
With this charging station you have decided for an advanced manufactured technology. 
The following features distinguish this charging stations from other similar technologies.  
 

 

Pulse charging with discharging pulse (NiCd/NiMh) 

 

Delta-Peak-Shutdown (NiCd/NiMH) 

 

Automatic transition to preservation mode after full charge  

 

Detection of defect batteries by electronic charging surveillance 

 

Effective charging current from 0,1 - 3,5 Ampere 

 

Protection of wrong polarity by acoustic signal  

 

Visualization of error message in case of max. charging time exceeding 

 

Charging of deep-discharged batteries (NiCd/NiMH) 

 

Error message in case of battery short-circuits 

 

Monitoring battery temperature 

 

Separate  switched-mode power supply for each battery compartment 

 

Optical visualization of charging status 

 

Programmable adapter system

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 

Summary of Contents for ULG 36-08

Page 1: ...Dreyer Strasse 6 8 Tel 0494203 4400 0 E Mail info jotbe com 28844 Weyhe b Bremen Fax 0494203 440010 Internet www jotbe com Battery charger ULG 36 08 Operation manual ...

Page 2: ...elta Peak Shutdown NiCd NiMH Automatic transition to preservation mode after full charge Detection of defect batteries by electronic charging surveillance Effective charging current from 0 1 3 5 Ampere Protection of wrong polarity by acoustic signal Visualization of error message in case of max charging time exceeding Charging of deep discharged batteries NiCd NiMH Error message in case of battery...

Page 3: ...e the battery charger in potentially explosive areas Defective fuses must only be replaced by the equal Types Only instructed or trained personnel are allowed to make changes at the battery charger The device must only be operated in dry rooms Ensure that there is sufficient ventilation for the device During operation the ventilation slits at the device must be open Otherwise the resulting heat ac...

Page 4: ... reason all optical indicator lamps are lighting up After 2 seconds the red indicator lamps switches off and the green indicator lamps make visible that the battery compartments are operation ready Charging After inserting the battery into the battery compartment the green indicator lamp should switching off and the red lamp should switching on The automatic charging process starts in this moment ...

Page 5: ...attery is charged in combination with the intended adapter Failure to observe may resulting damage to the batteries danger of explosion An additional information Should you charge older batteries NiCd NiMh which have been charged with conventional battery charger before a memory effect that eventually have already occured will be completely eliminated after repeated charging GREEN INDICATOR LAMP I...

Page 6: ...tone NTC break during charging process 8 x Signal tone TM content not correct 9 x Signal tone For NiCd NiMH more than 20 cells have been detected Troubleshooting Error Cause Solution After the device is switched on not all indicator lamps are lighting up There is an error inside the device Please contact our customer service After inserting the battery a signal tone sounds the adapter used is not ...

Page 7: ...e 1 2V 24V NiCd and NiMH batteries 3 6V 36V Li Ion and Li Po batteries 2V 24V PB accumulator Charging Current 0 1 3 5 Ampere effective Input 115V AC 50 60Hz 0 48KW Cooling Fan control thermal controlled Protection Class IP20 Dimensions weight ULG36 08 530 x 310 x 320 WxHxD in mm 19 kg We reserve the right to introduce technical changes without prior notice ...

Page 8: ...Dreyer Strasse 6 8 Tel 049 4203 4400 0 E Mail info jotbe com 28844 Weyhe b Bremen Fax 049 4203 440010 Internet www jotbe com 7 Notes ...