To prevent increased temperatures, you should not insert warm batteries into the battery
compartment. A battery for example being discharged under extreme pressure should not be directly
charged.
With the Delta-peak-detection (NiCd/NiMh) the device directly disconnect the battery from charging
current, if the battery reached its maximal capacity. Consequently, overcharge is excluded.
This means, that it is not necessary to remove a full-charged battery of the battery compartment.
After reaching the batteries maximal capacity, the corresponding battery compartment switches into
preservation mode. This balances the self-discharge caused by the internal resistance of the battery
and maintains the battery in an optimal charge condition.
You can recognize the availability of battery by the flashing green indicator-lamp.
The green indicator-lamp signals that the battery is full charged and in preservation mode.
Always make sure that the respective battery is charged in combination with the intended adapter.
Failure to observe may resulting damage to the batteries (danger of explosion)!
An additional information:
Should you charge older batteries (NiCd/NiMh) which have been charged with conventional battery
charger before, a memory-effect that eventually have already occured will be completely eliminated
after repeated charging.
GREEN INDICATOR-LAMP IS SWITCHING ON
I – OPERATION-READY
(THERE IS NO BATTERY INSIDE THE
BATTERY COMPARTMENT)
GREEN INDICATOR-LAMP IS FLASHING
I – BATTERY IS FULL-CHARGED
PRESERVATION MODE
RED INDICATOR-LAMP IS SWITCHING ON I – BATTERY IS CHARGING
RED INDICATOR-LAMP IS FLASHING I – s. CHAPTER TROUBLESHOOTING
Safety system:
The device is equipped with an extensive safety system.
After switching on the supply voltage the device controls the electronic components of the charging
technology by performing a self-test to localize errors. A simultaneous flashing of the red LED starts, if
the determined parameters are not conform to the saved parameters. In this case the respective
battery compartment will be completely interlocked for safety of the battery.
All these system controls occur parallel to the charging process. The described indication and shut
down will occur, if the self-test is not positive.