Error messages
(Error codes)
Errors, concerning the battery, will be showed by a slow flashing of the red LED. Until removal of the battery,
the battery compartment is locked. After removing the battery an acoustic signal shows the sort of error and
the battery compartment is ready for operation. The following error codes describe possible errors:
Error code
Error description
1 x Signal tone
Break inside the battery / no voltage potential establishment
2 x Signal tone
Temperature element has no contact
3 x Signal tone
Initial charging time exceeded / resuscitation not possible
4 x Signal tone
Charging time exceeded
5 x Signal tone
The battery becomes too warm
6 x Signal tone
Ident line or TM connection defect
7 x Signal tone
NTC-break during charging process
8 x Signal tone
TM content not correct
9 x Signal tone
For NiCd/NiMH more than 20 cells have been detected
Troubleshooting:
Error
Cause
Solution
After the device is switched on
not all indicator lamps are
lighting up
There is an error inside the device Please contact our customer service
After inserting the battery a
signal tone sounds
the adapter used is not
compatible with battery type
Use an adapter that is compatible with the
battery
The inserted battery is defect
Exchange the defect battery
After inserting the battery the
red indicator-lamp is flashing
the adapter used is not
compatible with battery type
Use an adapter that is compatible with the
battery
A thermoelement in the battery is
defect
Exchange the defect battery
After near to 100 min the red
indicator-lamp is flashing
The maximal charging time is
exceeded
Exchange the defect battery
Despite full charge level, the
battery does not bring highest
performance
One or multiple cells of the
battery are defect
Exchange the defect battery