Maintenance
The Tron 40VDR requires the following maintenance:
Timing
Requirements
Every
month
Both the EPIRB and the bracket should be inspected. The EPIRB
should be self-tested in the bracket.
Perform inspection and
testing following with steps outlined in this manual.
Every 4
th
month, perform an extended self-test (GPS test)
instead of the self-test.
Every
year
Test in accordance with MSC. 1040, the annual performance test.
Every 2
years
In addition to the regular yearly inspection and testing, the HRU
should be replaced including the plastic bolt. Mark the new expiry