82695
_Op&Ins MAN_TR2600_K 3-2
3.2
Using LAN interface
To get the TR-2600 running towards a Base Station Controller, please do the following steps:
1.
Connect the TR-2600 to the network by the RJ-45 connector in the adapter in the back of the
unit. The adapter is connected to the 9-pins D-sub labelled “LAN”.
2.
Set IP address and listen port for the unit. The listen port is the TCP or UDP port from
where the BSC will send messages, see section 5.3.2 and 5.3.2.1.
3.
Restart the TR-2600. Check that the unit is reachable on the network by doing a ping.
The TR-2600 is now available on the network. The unit supports both FTP and telnet in case this is
needed.
Now you have to decide whether you want to set up the Presentation Interface (PI) communication
via TCP or UDP.
3.2.1
TCP
The TR-2600 has a small TCP server built in, which serves the PI. The TCP server serves one
single client at a time. Messages that are sent on the TCP connection contains one NMEA message.
3.2.2
UDP
If UDP connection is wanted for the PI, the IP address and listen port for the BSC must be
specified. All the datagram that are sent from the TR-2600 is sent to this destination (also multicast
and broadcast is supported). Also here, one message per sent datagram.
1.
Set the BSC IP address and port as described in the operators manual ch. 5.3.2.2.
2.
Connect a “hyperterminal session” (delivered as a part of Microsoft Windows) to the TCP
connection with the listen port defined for the TR-2600. The commands for the
configuration of LAN connection are described in the Technical Manual ch. 5.3.7 and 5.3.8.
3.
The messages can be written in a text file (remember to end the file with a <CR><LF>) and
send it into the unit via the hyperterminal program.
4.
The command to set connection mode to UDP: $PJTR,211,2*1C
5.
Verify that the correct connection modus has been set by sending the command to request
the current connection mode: $PJTR,210,L*63 Then the current connection mode is
returned in the $PJTR,211,…
6.
Restart the unit and go…..
Summary of Contents for TR-2600
Page 1: ...OPERATION AND INSTALLATION MANUAL www jotron com TR 2600 AIS BASE STATION...
Page 53: ...82695_Op Ins MAN_TR2600_K 10 1 10 OUTLINE DRAWINGS 10 1 TR 2600 AIS BASE STATION...
Page 54: ...82695_Op Ins MAN_TR2600_K 10 2 10 2 TR 2600 AIS Transponder...
Page 55: ...82695_Op Ins MAN_TR2600_K 10 3 10 3 Procom CXL 2 1 l Maritime VHF Antenna with FLG Bracket...
Page 56: ...82695_Op Ins MAN_TR2600_K 10 4 10 4 Procom GPS 4 Antenna...
Page 61: ...82695_Op Ins MAN_TR2600_K 11 2...