Before Starting: Be sure to read and understand each step prior to attempting. Waiting too long in
between steps will cause the scanner to time out.
To Program New Users or Additional Fingers
Only Master User finger will be able to program additional fingers/users.
Step1)
- Master User step
Press white program button on control unit.
Step 2)
- Master User step
Scan Master User finger to unlock firearms. Press white program button and wait 15 seconds for
ORANGE LED prompt to scan Master User finger a second time. Remove Master User finger quickly as
GREEN LED prompts for New User finger.
Step 3) – New User step
During GREEN LED prompt, scan New User finger by pressing firmly and holding new finger still for
three continuous beeps. Remove finger after third beep.
Step 4) – New User step
Wait for scanner to cycle power and come up to RED LED.
Step 5) – New User step
During RED LED prompt, scan new finger to open lock(s) and verify setup.
Note: Adjust finger slightly if lock(s) do not open within 1 to 2 seconds.
Note: If scanner has multiple beeps after third New User finger scan, one of the finger scans had a bad
read.
To ensure best performance repeat New User Programming steps over.
Do not erase, unless reprogramming all users including Master User.