4
1.0 Relationship to the
authorities
• Installation of a
fi
replace must be according to local codes
and regulations in each country.
• All local regulations, including those which refer to national
and European standards, must be observed when
installing the product.
• The installation can only be put into use after it has been
checked by a quali
fi
ed inspector. Contact your local
building authorities before installing a new
fi
replace.
2.0 Technical data
Material:
Cast iron
Finish:
Black paint
Fuel:
Wood
Log length, max.:
35 cm
Flue outlet:
Top, rear
Flue pipe dimension:
- inside:
Ø125mm/123cm
2
cross-section
- exterior:
Ø150mm/177cm
2
cross-section
Approx. weight:
Jøtul F 100 ECO.2 LL /
Jøtul F 100 ECO.2 LL SE
89 kg
Jøtul F 100 ECO.2 SL /
Jøtul F 100 ECO.2 SL SE
88 kg
Optional extras:
Extra heat shield, rear
Dimensions, safetydistances:
See
fi
g. 1
Technical data in acc. with EN 13240
Nominal heat output:
4,9 kW
Flue gas volume:
4,1 g/s
Chimney draught, EN 13240:
12 Pa
Recommended negative pressure
in smoke outlet:
16 - 18 Pa
E
ffi
ciency:
80%
CO emissions (13% O2):
0,10
%
CO emissions (13% O2):
1213 mg / Nm3
NOx at 13% O2:
86 mg / Nm
3
OGC (13 % O2):
98 mg C /Nm3
Air consumption:
15-20 m3/h
Chimney temperature, EN 13240: 271
0
C
Dust:
25
mg/Nm3@13%O2
Particle emission NS 3059:
3,7 g / kg
Type of fuel:
Wood
Recommended log length:
25-33 cm
Max. log length:
35 cm
Fuel consumption:
1,56 kg/h
Max. kindling amount:
2,1 kg
Nominal kindling amount:
1,23 kg
Operation:
Intermittent
Intermittent combustion in this context means normal use
of the
fi
replace, i.e. fuel is added as soon as the fuel has
burnt down to a suitable amount of embers.
Register your
fi
replace at jotul.com for a
25-year warranty.
Table of contents
Installation manual with technical data
1.0 Relationship to the authorities ............................ 4
2.0 Technical data .................................................... 4
3.0 Safety ................................................................. 5
4.0 Installation ......................................................... 7
5.0 Daily use ............................................................. 13
6.0 Maintenance ....................................................... 14
7.0 Service................................................................ 15
8.0 Operational problemes -
troubleshooting ......................................................... 17
9.0 Optional Equipment ........................................... 17
10.0 Recycling .......................................................... 17
11.0 Guaranee terms ................................................ 17
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Lot no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Lot no. Pin.
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number when
contacting your retailer or Jøtul.
ENGLISH