39
139467_03 GF 370 DV II June 2015
3. Turn off all electrical power to the appliance if
service is to be performed.
4. Close control access door.
FOR YOUR SAFETY, READ BEFORE LIGHTING.
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. This appliance is equipped with an ignition
device which automatically lights the pilot.
Do not try to light the pilot by hand.
B. BEFORE LIGHTING, smell all around the appli-
ance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle to the floor.
WHAT TO DO IF YOU SMELL GAS:
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone.
• If your gas supplier cannot be reached, call the
fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the knob
will not push in or turn by hand, do not try
to repair it. Call a qualified technician. Force
or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
1. Set the thermostat to the lowest setting.
2. Set the Burner Control Switch to the
“OFF” position.
TO TURN OFF GAS TO THE APPLIANCE:
PILOT LIGHT FLAME PATTERN
1. STOP! Read the safety information above.
2. Set the thermostat to the lowest setting.
3. Set the Burner switch to the “OFF” position.
4. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to
light the pilot by hand.
5. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas,
STOP! Follow “B” in the safety information above on
this label.
If you do not smell gas, go to the next step.
6. Set the Pilot Mode switch to CPI for continuous op-
eration. The pilot will light. Set Pilot to IPI for thermo-
static operation. The pilot will light when there is a
call for heat.
7. Set the Burner switch to the “ON” or “T-STAT” position.
8. Set the thermostat to the desired setting to light
the burner. If the appliance will not operate, follow
the instructions, ”To Turn Off Gas To Appliance”, and
call your service technician or gas supplier.
PILOT MODE AND BURNER CONTROLS
IPI
CPI
ON
OFF
T-STAT
Proflame 2
Remote
BURNER
PILOT MODE
M