2
139775_R
03
_GI 535 DV IPI June 2016
66.96%
Natural Gas
Jøtul GI 535 DV IPI
�
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI
Gas Specialists.
Installation Requirements
for the Commonwealth of
Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GAS-FITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
1. If there is not one already present,
on each floor level where there are
bedroom(s), a carbon monoxide
detector and alarm shall be placed in
the living area outside the bedroom(s).
The carbon monoxide detector shall
comply with NFPA 720 (2012 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses
the appliance or equipment;
b) Be either hard-wired or battery
powered or both; and
c) Shall comply with NFPA 720 (2012
Edition).
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used.
Installation shall be in strict compliance
with the manufacturer’s instructions.
A copy of the installation instructions
must remain with the appliance or
equipment at the completion of the
installation.
THIS OWNER’S MANUAL PROVIDES INFORMATION TO
ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE
OPERATION OF YOUR FIREPLACE INSERT. PLEASE READ
THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THIS GAS
INSERT.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
67.84%
Propane
PLEASE NOTE:
It is normal for smoke and odor to occur during
the initial stages of operation, depending upon
temperatures generated over time. This “curing”
condition can be alleviated by promoting fresh
air circulation within the immediate vicinity of
the appliance.
Suggested Tools for Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• A manual shut-off valve is included with this appliance,
however, an additional T-Handle valve may be required in
Massachusetts
• Sediment trap
- if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2”, 7/16” open end wrench
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• Work Gloves
• Safety glasses
• Torx T-20 screwdriver
• Tin snips
• Glass Latch Tool
- included with appliance.
Retain and store as shown in fig. 7.3.
Based on CSA P.4.1-15