background image

2

Read the instructions contained in this booklet

carefully before using the appliance.

Joukle cannot assume any responsibility for da-

mage to property or personal injury resulting

from failure to abide by the instructions given in

this booklet.

Following these instructions will ensure a long

service life and overall electrical and mechanical

reliability.

Keep this instruction booklet in a safe place.

Table of Contents

EN

Compliance with Building Codes  . . . . . . 3
Description . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operating Principles . . . . . . . . . . . . . . . . . 5
Instructions for Use . . . . . . . . . . . . . . . . . 5
Maintenance/Cleaning . . . . . . . . . . . . . . . 5
Information for the Installer . . . . . . . . . . . 5
Important information on eco- 
compatible disposal. . . . . . . . . . . . . . . . . . . . . . 9

 A

 A

A

Check that the power supply specifica-
tions comply with the electrical data on
data plate A

Summary of Contents for InvaVent MAXI

Page 1: ...Instruction booklet COD 5471 084 960 09 03 2018 MAXI ...

Page 2: ...structions will ensure a long service life and overall electrical and mechanical reliability Keep this instruction booklet in a safe place Table of Contents EN Compliance with Building Codes 3 Description 3 Safety 4 Operating Principles 5 Instructions for Use 5 Maintenance Cleaning 5 Information for the Installer 5 Important information on eco compatible disposal 9 A A A Check that the power suppl...

Page 3: ...rbon zero by 2016 the INVAVENT MAXI has been designed future proof The Code for Sustainable Homes which came into force in March 2007 details six levels of CO2 emission improvement over 2006 Building Regulations requirements To achieve the three highest levels of reduction of carbon emissions the air leakage of the dwelling must be improved so significantly that continuous ventilation becomes the ...

Page 4: ...appliance where flammable vapours are present spirit insecticides petrol etc The appliance houses electrical components in the event of malfunction call a qualified technician The appliance houses moving parts that can still be in motion several seconds after the unit has been disconnected from the mains For this reason you are advised to disconnect the appliance from the mains then wait at least ...

Page 5: ...eas of the home The volume of air to be extracted is set by moving adjustable vents in line with unit requirements and current legislation Incoming air on the other hand enters via intakes e g grilles positioned on the walls or windows of lived in areas Appliances from the INVAVENT MAXI are designed to ensure comfort in the home with the least possible use of electricity Instructions for use INVAV...

Page 6: ...tings are Vmax 600 and Vmin 400 Setting procedure with the speed selector circuit breaker closed change Vmax from 600 to 2500 rpm fig 5 open the speed selector circuit breaker change Vmin from 400 to Vmax fig 6 wait 5 minutes for the appliance to memorise the new settings turn the power supply to the appliance OFF turn the appliance back ON and check that the new settings have been successfully st...

Page 7: ...INVAVENT MAXI Make sure that the blades rotate smoothly on the driveshaft on completion of the cleaning reposition the blanking caps where they were beforehand reconnect the appliance to the mains Vents should be cleaned regularly to ensure that the unit is working at its best and that the areas involved are being well ventilated Make sure that system settings are not interfered with Each vent sho...

Page 8: ...8 ENGLISH 11 11 MAXIMUM SPEED L N N1 L2 3 4 10 10 MEDIUM SPEED L N N1 L2 3 4 L N N1 L2 3 4 9 9 MINIMUM SPEED ...

Page 9: ...a collection centre for waste electrical and electronic equipment or returned to a retailer on purchase of a replacement It is the user s responsibility to dispose of this appliance through the appropriate channels at the end of its useful life Failure to do so may incur the penalties established by laws governing waste disposal Proper differential collection and the subsequent recycling processin...

Page 10: ...10 ENGLISH ...

Page 11: ...11 ENGLISH ...

Page 12: ...eb www joule ie JOULE UK mail Unit 17C D Power Road Plantation Bus Pk Bromborought Wirral CH62 3RN tel 44 0 1513 551 094 fax 44 0 1513 568 336 eml info jouleuk co uk web www jouleuk co uk JOULE PL mai 23 200 Kraśnik ul Towarowa 34 tel 48 0 128811171 fax 48 0 814709046 eml biuro joule pl pl web www joule pl pl ENGLISH ...

Page 13: ...13 ENGLISH ...

Page 14: ...NTRE CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE DATE OF WORK STAMP OF TECHNICAL ASSISTANCE CENTRE CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE DATE OF WORK STAMP OF TECHNICAL ASSISTANCE CENTRE CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE DATE OF WORK STAMP OF TECHNICAL ASSISTANCE CENTRE B C D ...

Page 15: ...ned to your approved stockist This portion of the guarantee should be attached to the appliance UK IRELAND Send the guarantee in sealed envelope to Joule Kylemore Park West Ballyfermot Dublin 10 OTHER COUNTRIES Please send the guarantee to the retailer s address in the country where the appliance has been purchased I authorize to include my personal details within their database which they use via...

Page 16: ...uarantee is only valid if all details are completed correctly Mailing date Stamp of supplier TO SEND within 8 days from the date of purchese Stamp of supplier Purchase date CUSTOMER DATA name surname street post code town I have read and understood the terms and conditions of this guarantee and I authorize the processing of my personal details see overleaf Signature Mailing date ...