• Under normal conditions, a module is likely to produce more current and/or voltage
than reported under Standard Test Conditions (STC). Accordingly, the values of ISC
and VOC marked on the module nameplate should be multiplied by a factor when
determining the component voltage ratings, conductor current ratings, fuse sizes,
and the size of controllers connected to the photovoltaic system. The exact factor
value should be suggested by a licensed/qualified person.
• The connecting ends with electricity may cause fire, spark or lethal shocks even
when the modules are not connected.
• Electricity can be generated when the modules are exposed to sunlight, even if
they are not connected. It is dangerous to touch 30V DC or higher, so never open
the electrical connectors or unplug the electrical connectors while the circuit is
under load, and do not touch the end with electricity during installations, when the
modules are exposed to sunlight.
• Children should be kept away from the photovoltaic system.
• In order to prevent current and voltage generation during installation an opaque
board can be used to cover the modules.
• Only use licensed/qualified insulated tools.
• The frame of the modules must be grounded according to local, regional and state
safety and electrical standards. A recommended connector or equivalent must be
used for the grounding cable. The grounding cable must be appropriately fastened
to the module frame.
• Only Balance of System (BOS) in conformity to local, regional, state safety electricity
standards and photovoltaic system such as connectors, cables and frames can be
used, avoiding affect on the module performance and/or damage it.
Fire Safety
• Consult your local authority for guidelines and requirements for building or struc-
tural fire safety.
• Roof constructions and installations may affect the fire safety of a building; an im-
proper installation may create a hazard in the event of a fire.
• Use components such as ground fault circuit breakers and fuses as required by the
local authorities.
• Do not use the modules near a location where flammable gases are either gener-
ated or collected.
• The modules have been rated Fire Class C, and are suitable for mounting onto a
Class A roof.
Summary of Contents for Pulsa PV
Page 1: ...PULSA PV joule pulsa pv solar high performance ac solar module installation guide...
Page 2: ......
Page 4: ......
Page 10: ...Maximising Performance 10 Locating the Unit...
Page 11: ...Transportation and Installation Notes 11 PULSA PV installation manual...
Page 15: ...15 PULSA PV installation manual...
Page 29: ...29 PULSA PV installation manual...
Page 32: ...32 Locating the Unit Electrical Installation Microinverter Technical Specification...
Page 33: ...33 PULSA PV installation manual...
Page 42: ......
Page 43: ......