Mechanical Installation
18
Locating the Unit
Roof fixing bolts are drilled down through the slate or tile covering the roof. The rub-
ber gasket on the bolt keeps the penetration point in the roof weather proofed. A UV-
resistant EPDM gasket with sealing cone and support collar is counter screwed with
a third mounting nut and safely seals the roof. The roof fixing bolt bolt is connected
to the profile by use of a stainless steel clamp of which one side which slides into the
square side of the horizontal profile. The bolt head slides through the profile to the
desired location where the second side of the clamp locks the profile into position.