background image

 

 

3. ASSEMBLY OF VERSION B

 

This case is made for the JT

-

RD6006 / JT

-

RD6006P and the related power 

supply  JT

-

RD6006

-

NT.  Both  products  are  not  included  in  the  scope  of 

 

delivery.

 

 

1.

 

Screw the feet onto the case with the black screws.

 

2.

 

Now, place the switch, the power connector, the fan control and the 

fan in the enclosure and screw them in place with the silver screws 

and nuts, if necessary. Place the temperature sensor board on the 

back  of  the  fan  control  and  screw  them  both  into  the  enclosure

 

together.

 

Summary of Contents for 4250236820477

Page 1: ...e is available in two versions version A and B These versions differ by a lead out of the temperature sensor which only version B features This case is made for an additional power supply which allows...

Page 2: ...T Both products are not included in the scope of delivery 1 First of all unscrew the eight screws from the outside and open up the case 2 Screw the feet onto the case with the black screws 3 Now inser...

Page 3: ...wiring You start by wiring the switch First connect the short brown cable phase to the switch and the bottom connection of the power connector From the switch connect another brown cable to the screw...

Page 4: ...e fan controller and the RD6006 power supply unit to the V terminals and the red cables to the V terminals 8 Now you have to connect the last loose cable with the RD6006 Therefore the black cable will...

Page 5: ...of the RD6006 NT with the help of the fine tuning potentiometer You can see your adjustment at the input voltage of your RD6006 RD6006P Ideally the RD6006 RD6006P has an input voltage of 65 V to be ab...

Page 6: ...the scope of delivery 1 Screw the feet onto the case with the black screws 2 Now place the switch the power connector the fan control and the fan in the enclosure and screw them in place with the sil...

Page 7: ...ew terminal of the power supply unit marked as L The blue cable is connected from the middle connection of the power connection to the N connection of the power supply unit The yellow green cable is c...

Page 8: ...ed between IN on the RD6006 and V on the power supply and the red cable between IN on the RD6006 and V on the power supply 7 You can also connect the connector from the temperature sensor lead out if...

Page 9: ...of the RD6006 NT with the help of the fine tuning potentiometer You can see your adjustment at the input voltage of your RD6006 RD6006P Ideally the RD6006 RD6006P has an input voltage of 65 V to be ab...

Page 10: ...hold quantities 1 Possibility of return at our company location during our opening hours Simac Electronics Handel GmbH Pascalstr 8 D 47506 Neukirchen Vluyn 2 Possibility of return nearby We will send...

Reviews: