6.

 

Now, you have to connect the last loose cables with the RD6006 and 

 

the  power  supply.  Therefore,  the  black  cable  will  be  connected 

 

between IN–

 

on the RD6006 and V–

 

on the power supply

 

and  the  red 

 

cable between IN+ on the RD6006 and V+ on the power supply.

 

7.

 

You  can  also  connect  the  connector  from  the  temperature  sensor 

 

lead

-

out if you want to lead the temperature sensor outside of the 

 

case.  Otherwise,  connect  the  temperature  sensor  now  to  the 

 

RD6006 / RD6006P. 

 

Summary of Contents for 4250236820477

Page 1: ...e is available in two versions version A and B These versions differ by a lead out of the temperature sensor which only version B features This case is made for an additional power supply which allows...

Page 2: ...T Both products are not included in the scope of delivery 1 First of all unscrew the eight screws from the outside and open up the case 2 Screw the feet onto the case with the black screws 3 Now inser...

Page 3: ...wiring You start by wiring the switch First connect the short brown cable phase to the switch and the bottom connection of the power connector From the switch connect another brown cable to the screw...

Page 4: ...e fan controller and the RD6006 power supply unit to the V terminals and the red cables to the V terminals 8 Now you have to connect the last loose cable with the RD6006 Therefore the black cable will...

Page 5: ...of the RD6006 NT with the help of the fine tuning potentiometer You can see your adjustment at the input voltage of your RD6006 RD6006P Ideally the RD6006 RD6006P has an input voltage of 65 V to be ab...

Page 6: ...the scope of delivery 1 Screw the feet onto the case with the black screws 2 Now place the switch the power connector the fan control and the fan in the enclosure and screw them in place with the sil...

Page 7: ...ew terminal of the power supply unit marked as L The blue cable is connected from the middle connection of the power connection to the N connection of the power supply unit The yellow green cable is c...

Page 8: ...ed between IN on the RD6006 and V on the power supply and the red cable between IN on the RD6006 and V on the power supply 7 You can also connect the connector from the temperature sensor lead out if...

Page 9: ...of the RD6006 NT with the help of the fine tuning potentiometer You can see your adjustment at the input voltage of your RD6006 RD6006P Ideally the RD6006 RD6006P has an input voltage of 65 V to be ab...

Page 10: ...hold quantities 1 Possibility of return at our company location during our opening hours Simac Electronics Handel GmbH Pascalstr 8 D 47506 Neukirchen Vluyn 2 Possibility of return nearby We will send...

Reviews: