4.3.5 Control board wiring
4.3.5.1 Standard control board
+
+
O
+
24VDC
24VDC
GND
GND
I.R
I.R
CLLM
CLLM
COM
COM
OPLM
OPLM
COM
COM
STP
STP
X5
X5
10A
10A 250V
250V
CLS
CLS
OPN
OPN
X1
X1
W U V PE
PE
D2
D2 D1
D1 C C
SW1
SW1
ON
ON
AN1
AN1
LED1
LED1
X2
X2
X3
X3
PE
PE N L
X8
X8
M
24VDC
24VDC
GND
GND
Power
Power
Lamp
Lamp Capacitor
Capacitor
Infrared
Infrared sensor
sensor
Limit
Limit switch
switch
Earth
Earth
LED2
LED2
External
External button
button
switch
switch
X7
X7
Motor
Motor
Figure 18
Wiring instruction:
1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is live wire, N is
Neutral wire, and PE is grounding wire.
2. Connect LAMP to D1, D2; voltage: AC220V/50HZ; AC110V/60HZ.
3. Connect the motor wire U to the REV motor wire, connect W to the FWD motor wire, and
connect V to the motor common wire.
4. Connect C, C to the capacitor wire.
X5 Terminal
24VDC
Power supply for fi24VDC
(
Electric current ≤50mA
)
;
GND
Power ground;
I.R
Photocell input (N.C.);
CLLM
Close limit switch;
COM
Limit switch common terminal;
OPLM
Open limit switch.
X7 Terminal
COM
Control button common terminal;
STP
Stop control button (N.O.);
CLS
Gate close control button (N.O.);
OPN
Gate open control button (N.O.).