background image

SL600AC SLIDING GATE OPERATOR 

                                                                                       

20 

11. Troubleshooting  

Trouble Possible 

causes  Solutions 

The door fails to 
open and close. 
LED display 
does not light. 

1. Power is OFF 
2. Fuse burn 

1. Make sure that 
power is ON. 
2. Replace fuse. 

The door can 
open fails to 
close. 

1. Infrared beam is 
obstructed. 
2. Infrared sensor 
function is enabling, but 
the sensor has not been 
installed. 

1. Remove 
obstructions. 
2. Make sure the 
infrared sensor 
function is disabling. 

Remote 
transmitter does 
not work. 

1. Battery level may be 
low 
2. Transmitter code is 
lost 

1. Replace the 
battery inside the 
transmitter. 
2. Reprogram the 
transmitter. 

The transmitter 
operating 
distance is too 
short. 

Battery level may be 
low. 

Replace battery. 

 
 
 
 
 
 
 
 
 
 

SL600AC SLIDING GATE OPERATOR 

                                                                                       

21

11.  Packing list 

After receiving the gate operator, you should make an 
unpack-inspection, in which you should check whether the product 
was damaged. If you have any problem please contact our dealer. 
You should find the following items in our standard packing: 
 

 

No. Item Quantity 

  SL600AC sliding gate 

operator 

Transmitter 

Release key 

User’s manual   

 
 

Summary of Contents for SL600AC

Page 1: ...urposes 2 Important safety information Carefully read and follow all safety precautions and warning before attempting to install and use this automatic gate operator z The gate operator should be inst...

Page 2: ...0ACU Power supply 220V 50Hz 110V 60Hz Motor speed 55rpm 66rpm Rated output power of motor 180W Remote control operating distance 30m Frequency 433 92mHz Remote control mode Single button Output shaft...

Page 3: ...d should be approximately 450mm x 300mm x 200mm deep in order to providing for adequate weight and structure to insure proper stable installation Anchors see Fig 2 You can use anchor bolts anchors was...

Page 4: ...s are used to control the position of the gate SL600AC SLIDING GATE OPERATOR 7 z Release the gear with the key and push the sliding gate manually to pre determine the position fix the block to the rac...

Page 5: ...z Turn the key and pull down the release bar about 90 to release the gear Note Do not exceed 90 be careful not to use too much force otherwise the release bar will be damaged z Open and close the gate...

Page 6: ...Infrared If the infrared beam is interrupted during closing the gate will reverse and open immediately The product is not factory equipped with an infrared device the infrared output signal must be N...

Page 7: ...PE Protect Earth C and C capacitor If the door move direction is wrong please change the MOT1 and MOT2 of motor and change the block of SL600AC SLIDING GATE OPERATOR 13 limit Magnetic limit switch Mot...

Page 8: ...emote Pedestrian button After you learn the transmitter you press the remote button 4 the door will open 1 meter when the door is closed z You can program learn button 1 button 2 and button 3 individu...

Page 9: ...When the 3 OFF and the 4 is ON auto close time is near 12 Sec when the 3 ON and the 4 is OFF auto close time is near 24 sec when the 3 and the 4 is all in ON position the auto close time is near 36 s...

Page 10: ...120 C and switch on the motor automatically when the temperature is lower than 85 C 5 C 9 LED indicate a LED of Power indicated the input power b LED of LEARN indicated the transmitter learn status c...

Page 11: ...mote transmitter does not work 1 Battery level may be low 2 Transmitter code is lost 1 Replace the battery inside the transmitter 2 Reprogram the transmitter The transmitter operating distance is too...

Reviews: