background image

INSTRUCTION MANUAL      CODE  80154   REV B       March/2017 

 

   (It can be modi

 ed without notice)              Page:  1

J

.P.  SELECTA s.a.u. 

 

Ctra. NII Km 585.1 Abrera  08630  (Barcelona) España 

Tel (34 93) 770 08 77  Fax (34 93) 770 23 62

 e-mail: selecta@jpselecta.es -  http://www.jpselecta.es

 

 

 

VB-1423 

 

 

3001423

 

 

BAÑO DE PRECISIÓN PARA VISCOSÍMETROS "VB-1423"

PRECISION VISCOSIMETER BATH "VB-1423"

Summary of Contents for 3001423

Page 1: ...ut notice Page 1 J P SELECTA s a u Ctra NII Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 93 770 08 77 Fax 34 93 770 23 62 e mail selecta jpselecta es http www jpselecta es VB 1423 3001423 BA O DE PRE...

Page 2: ...e mail selecta jpselecta es http www jpselecta es INDICE INFORMACI N GENERAL 3 LISTA DE EMBALAJE 3 ACCESORIOS 4 CARACTER STICAS EQUIPO 4 ESPECIFICACI N T CNICA 5 INSTALACI N 5 OPERACI N 6 MANTENIMIEN...

Page 3: ...rte inseparable del aparato y deben estar disponibles a todos los usuarios del equipo 4 Cualquier duda puede ser aclarada contactando con el ser vicio t cnico de J P SELECTA s a u 5 ATENCI N NO SE ADM...

Page 4: ...1457 De 60 0 C a 90 0 C dividido en 0 1 C 1001458 De 80 0 C a 110 0 C dividido en 0 1 C 1001459 CARACTER STICAS DEL EQUIPO Sensor de la temperatura por termoresistencia de Pt100 Tapa en acero inox AIS...

Page 5: ...115V 50 60Hz o 230V 50 60Hz seg n se indique en la placa de caracter sticas de la m quina Rango de regulaci n Regulation range 25 C 100 C Temperatura m xima Maximum temperature 100 C Estabilidad Stabi...

Page 6: ...93 770 23 62 e mail selecta jpselecta es http www jpselecta es OPERACI N PANEL DE MANDOS 1 Interruptor general 2 Regulador de temperatura 3 Display 4 Pulsador de aumento de valor 5 Pulsador de descen...

Page 7: ...ar una temperatura de trabajo que como m nimo sea 5 C menor que la anteriormente seleccionada El termostato de seguridad es especialmente pr ctico para usuarios que trabajen habitualmente a la misma t...

Page 8: ...tra el PV medido por el sensor de temperatura Termopar K conectado se muestra la temperatura correcta Otro termopar conectado no muestra la temperatura correcta SP EL ajuste por defecto es 0 C Si no u...

Page 9: ...REV B March 2017 It can be modi ed without notice Page 9 J P SELECTA s a u Ctra NII Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 93 770 08 77 Fax 34 93 770 23 62 e mail selecta jpselecta es http www...

Page 10: ...quipment and it must be available for all users 4 If you have any doubts or enquiries please contact with your supplier or J P Selecta s technical service 5 IMPORTANT J P SELECTA WILL NOT ACCEPT ANY E...

Page 11: ...At 60 0 C to 90 0 C Div scale 0 1 C 1001458 At 80 0 C to 110 0 C Div scale 0 1 C 1001459 EQUIPMENT FEATURES Temperature sensor Pt100 thermo resistor Stainless steel AISI 304 lid with three viscometer...

Page 12: ...60Hz or 230V 50 60Hz as indicated on the characteristics plate Rango de regulaci n Regulation range 25 C 100 C Temperatura m xima Maximum temperature 100 C Estabilidad Stability 0 05 C Resoluci n Res...

Page 13: ...70 08 77 Fax 34 93 770 23 62 e mail selecta jpselecta es http www jpselecta es OPERATION CONTROL PANEL 1 Main switch 2 Temperature regulator 3 Display 4 Increase value push button 5 Decrease value pus...

Page 14: ...ing temperature minimum at 5 C below the previous selected tem perature The safety thermostat is useful when the user works habitually at the same temperature MAINTENANCE Before removing the cover dis...

Page 15: ...08 77 Fax 34 93 770 23 62 e mail selecta jpselecta es http www jpselecta es STARTING UP GUARANTEE This product is guaranteed for one year The guarantee does not cover damage caused by incorrect use o...

Page 16: ...80154 REV B Marzo 2017 Sujetas a modi caciones sin previo aviso Pag 16 J P SELECTA s a u Ctra NII Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 93 770 08 77 Fax 34 93 770 23 62 e mail selecta jpselec...

Reviews: