Seal-355-3/5 User manual
14
2) SAMlight card
5. Operation
5.1 Turn on laser
1
)
connect chiller with laser water connector
,
lock tight
.
2
)
Turn on chiller
,
set temperature at 25
℃
,
until stable at 25±0.5
℃
3
)
check laser outlook condition
,
if any particle/sticker block output port, please remove it.
4
)
Make sure laser controller and laser head properly connected, check if marking system and
laser System been connected properly.
5
)
Switch on 12V DC power supply, turn on the key switch(before operation, we must connect
the control card and ensure that the card has been supplied to prevent laser damage).
Confirm there is no abnormal indicator, and wait for the laser to get stable then we can use
SAMlight card
PIN31 to LASER- and short
circuit
PIN1, PIN2 of J1
PIN13 to PWM
﹢
and short
circuit
PIN2, PIN3 of J2