27 | Installation Instructions
TB2
No.
Details
Description
No.
Details
Description
1
CTX+
Serial signal output to BAMS
(IEC62923-1/2 / 61162-1)
11
CIN+
Not Used
2
CTX-
12
CIN-
Not Used
3
CRX+
Serial signal input from BAMS
(IEC62923-1/2 / 61162-1)
13
COUT1
Not Used
4
CRX-
14
COUT2
Not Used
5
CSC
Serial signal common
15
24R
24V DC Power supply to DGC
6
ESTX+
Serial signal to DGC
16
24RC
GND Power supply to DGC
7
ESTX-
Serial signal output
– to DCG
17
BTPF
Not Used
8
ORX+
Not Used
18
BTPFC
Not Used
9
ORX-
Not Used
19
LOST
Not Used
10
OSC
Not Used
20
LOSTC
Not Used
TB3
No.
Details
Description
No.
Details
Description
1
24M+
Main Power input +24VDC
5
24B+
Backup supply of Power Supply Unit
2
24M-
Main Power input -24VDC
6
24B-
Backup supply of Power Supply Unit
3
24R+
Power Supply Unit 24R input
7
24BT+
Backup (emergency) Power input
+24VDC
4
24R-
Power Supply Unit 24RC input
8
24BT-
Backup (emergency) Power input -
24VDC
Table: Terminal TB2 & TB3 of Control Box ICNT Board Terminal
Summary of Contents for ALPHAMIDICOURSE Mk2
Page 80: ...80 Appendices 6 1 1 Dimensions of Control Unit...
Page 81: ...81 Appendices 6 1 2 Dimensions of Master Compass...
Page 82: ...82 Appendices 6 1 3 Master Compass without housing...
Page 84: ...84 Appendices 6 1 5 Connection Diagram...
Page 85: ...75 Appendices 6 1 6 Cable Diagram...
Page 86: ...76 Appendices 6 1 7 Installation Drawing...
Page 88: ...78 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 89: ...79 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 90: ...80 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 91: ...81 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 92: ...82 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 95: ...85 Appendices 6 4 Return Slip Sensitive element...
Page 96: ...86 Appendices...
Page 99: ......