76 | Maintenance
5.4.14 Alarm code r: E5V Failure
1.
Confirm that all equipment connected to this system operates properly.
Note
Refer to the As Built plan kept on board of the ship for the connected equipment.
2.
Operate it according to the particular Operator Manual of the equipment, when a failure has been activated.
3.
Contact Alphatron Marine Service Engineer, or agent, after checking steps 1 and 2.
5.5 Gyro Compass does not Function, when Power Switch turned ON.
• WARNING
• Pay full attention to avoid electric shock when checking the power supply.
• When checking fuses, turn "OFF" the power switch on the operating panel and further disconnect the power
cable
from the ship’s distribution board before checking fuses.
1.
Confirm there is power on the power supply cable and the emergency power supply.
Note
To confirm this, execute as in paragraph 5.4.1
Alarm code 1: Power Supply Failure.
2.
Check fuses F6 till F9 according to paragraph 5.8
Fuse Replacement
if there is no problem with the power supply.
3.
Contact Alphatron Marine Service Engineer, or agent, immediately after checking steps 1 and 2.
5.6 Alarm 3 and A are activated at the Same Time when Powering ON
1.
Turn OFF the power switch, when error code "3" and "A" are activated at the same time.
2.
Turn back ON after approx. 1 minute.
3.
Check the inverter fuse F1: 12A, located in the base of the master compass, refer to paragraph 5.8.1
Master Compass
Inverter Fuse.
5.7 Each repeater does not operate
• WARNING
• When checking fuses, turn "OFF" the power switch on the operating panel and further disconnect the power
cable from the ship’s distribution board before checking fuses.
1.
Confirm the power switch of the repeater(s) side.
2.
Check fuses F1 till F5 according to paragraph 5.8
Fuse Replacement
if there is no problem with step 1.
3.
Contact Alphatron Marine Service Engineer, or agent, immediately after checking steps 1 and 2.
5.7 Others
When failures and alarms, other than those mentioned before, are activated and when the replaced fuse has blown
again, take following actions:
1.
Turn OFF the power switch on the operating panel.
2.
Disconnect the power supply from the
ship’s distribution board, etc.
3.
Contact Alphatron Marine Service Engineer, or agent, immediately.
Note
In such event, prompt service action is available when the alarm code is advised.
Summary of Contents for ALPHAMIDICOURSE Mk2
Page 80: ...80 Appendices 6 1 1 Dimensions of Control Unit...
Page 81: ...81 Appendices 6 1 2 Dimensions of Master Compass...
Page 82: ...82 Appendices 6 1 3 Master Compass without housing...
Page 84: ...84 Appendices 6 1 5 Connection Diagram...
Page 85: ...75 Appendices 6 1 6 Cable Diagram...
Page 86: ...76 Appendices 6 1 7 Installation Drawing...
Page 88: ...78 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 89: ...79 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 90: ...80 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 91: ...81 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 92: ...82 Appendices AlphaMidiCourse Mk2 Check Maintenance Sheet...
Page 95: ...85 Appendices 6 4 Return Slip Sensitive element...
Page 96: ...86 Appendices...
Page 99: ......