2.2.2
Scan test screen example (not during testing)
An example of a scan test screen (not during scanning) is shown in Fig. 2-5
Fig. 2-5 Sensing test screen example (not during sensing)
(6)
Antenna Mark
(11)
Cursor mark coordinates
(10)
Display range
(13)
External output display
(12)
Image processing display
(9)
Battery capacity display
(5)
Sensitivity display
(4)
Cursor
(3)
Depth gauge
(1)
Depth calibration value
(8)
Distance moved gauge
(7)
Cursor Coordinates
(2)
Calibration method
(1)
Depth calibration value
Displays the depth calibration value set at the parameter settings screen.
The method for setting the depth calibration value can be found in section 2.3.6 “Depth
Calibration”.
(2)
Calibration method
Displays the calibration method set using the parameter settings screen.
Distance feed system displays “m” and time feed system displays “s”.
The method for setting the calibration method can be found in section 2.3.5 “Calibration
Method”.
(3)
Depth gauge
Displays a scanning depth gauge.
The scanning depth gauge changes based on the depth calibration value.
‑ 16 ‑
Summary of Contents for Handy Search NJJ-95B
Page 1: ...Handy Search Instruction Manual...
Page 8: ...Appearance of the NJJ 95B vii...
Page 21: ...Rear view Units in trigonometry mm 9...
Page 24: ...8 14 15 Figure 2 2 Side View 16 17 14 18 Figure 2 3 Rear View 12...
Page 73: ...Display of thumbnails Figure 3 17 CF Control Screen 61...
Page 83: ...B Terminals ACharge confirmation mark Figure 3 22 Battery Pack 71...
Page 85: ...Shutter Charge lamp Figure 3 23 Battery Charger 73...
Page 96: ...Concrete Rebar D 75mm L 75mm D 75mm Difficult to implement 84...
Page 103: ...Dimensions Weight About 149 W x 147 H x 216 D mm Approximately 1 1kg 91...