1. Operation
6
1.3.2 Stopping the System
y
To stop the equipment, follow the procedures described below.
ATTENTION
To operate the
RCU
, the
front door
has to be unlocked and opened.
ATTENTION
Do not turn off the breaker of the power distribution board while the
system is active. Otherwise, the system is battery-operated by
PSU
.
ATTENTION
Before turning off
RCU
, be sure to stop recording data to
CF CARD
by
pressing
CARD STOP
switch
on
MCB
. Otherwise, data may not be
able to
be
recorded to
CF CARD
.
1. Stopping the Recording Control Unit
1) Unlock the front door with the key and open it.
2) Be sure to stop recording data to the
CF CARD
by pressing the
CARD STOP
switch
on
the
MCB
.
y
Make sure that the
CARD LED
on the
MCB
is off.
y
Be aware that if the
Power Supply
is turned off while the
CARD LED
is on, data may
not be recorded to the
CF CARD
.
3) Turn off the
Power
switch
of the
PSU
.
4) Then all the
LED
s are turned off.
2. Stopping the Operation Panel Unit
If the
PSU
in the
RCU
is turned off, the
OPU
is also turned off.
3. Stopping the Protective Capsule Unit
If the
PSU
in the
RCU
is turned off, the
PCU
is also turned off.
4. Stopping the Microphone Unit
If the
PSU
in the
RCU
is turned off, the
MIC
is also turned off.
5. Stopping the Option Units
If the
PSU
in the
RCU
is turned off, the
Option Units
are also turned off.
Summary of Contents for JCY-1800 -
Page 2: ......