10. Specifications
Display
10.4 inch TFT LCD (640 x 480 pixels)
Frequency
200kHz / 50kHz or 50kHz-A
Echo color
8 colors or 8 level monochrome
Digital depth
3 digit (0.0m to 99.9m : 0.1m steps, 100m over : 1m steps)
Range
10m
20m
50m
100m
200m
500m
800m
Sounding
capability
(Note1)
200kHz 1.0m
to 10m
1.0m
to 20m
1.5m
to 50m
2.0m
to 100m
3.0m
to 200m
5.0m
to 300m
7.0m
to 300m
50kHz
or 50kHz-A
2.0m
to 10m
2.0m
to 20m
3.0m
to 50m
3.0m
to 100m
4.0m
to 200m
6.0m
to 500m
8.0m
to 800m
TX pulse
repetition rate
pulse per
minute
171
PPM
171
PPM
171
PPM
86
PPM
86
PPM
43
PPM
43
PPM
Accuracy
0.5m : 20m range, 5m : 200m range; or 2.5% of the indicated depth, whichever is
greater
Draft adjust
0m to 50m in 0.1m steps
Display mode
Standard, History, Docking
Time range of
echo display
5, 10, 20, 30min
Auto function
Gain, Range
Alert function
Depth, Power fail, System error
Preview function 12hour or 24hour
Transducers
200kHz : UT-200ND , 50kHz or 50kHz-A : UT-50MD
Power supply
100-115/200-230VAC
±
15%, 50Hz/60Hz
±
5% less than 50W
24VDC (only use for power fail monitoring)
Water proofing
IPX2 drip proof
Input nav. data
IEC61162-1NMEA0183 RMA, RMC, GGA, GLL, ZDA
Input ACK signal IEC61162-1NMEA0183 V1.5, V2.3 ACK V5.0 ACN
Input signals
Power fail alert ACK:
(Contact input: 12VDC 2.4mA, current control: 12VDC 1.2mA)
Depth alert ACK, System alert ACK:
(Contact input: 5VDC 5mA, current control: 12VDC 1.2mA)
Output depth
value data
IEC61162-1 (NMEA0183 V1.5)
IEC61162-1 (NMEA0183 V2.3, V5.0)
DBS, DBT, DBK
DPT
every 1 second
every 1 second
Output alert data IEC61162-1 (NMEA0183 V1.5, V2.3)
IEC61162-1 (NMEA0183 V5.0)
ALR
ALC, ALF, ARC, HBT
every 1 second
every 1 second
Output system
data
(IEC61162-1)
PJRCL
PJRCM (90)
PJRCM (88, 89)
UTC
UTC
every 10 seconds
every 0 to 4 hours
every 0 to 4 hours
Output PC data PJRCP
Output signals
Power fail alert, Depth alert, System alert:
(Relay contact output: rated load 120VAC 10A, 30VDC 8A, NO/NC)
Temperature
–15°C to +55°C / operating –25°C to +70°C / storage
Humidity
less than 93%RH under +40°C condition (non-condensing)
Note1: Sounding capability may vary in frequency, gain setting, bottom shape, sea state, vessel speed,
etc.
10. Specification 66
Summary of Contents for JFE-680 -
Page 2: ......
Page 9: ...External View External View vii NO ALERT ...
Page 18: ...1 5 System Configuration 1 Introduction 6 alert alert alert alert alert alert alert ...
Page 54: ...5 1 Installing the Recorder Unit Flush Mount Equipment Figure 3 1 5 Installation 42 Unit mm ...
Page 55: ...Wall Mount Equipment Figure 3 2 5 Installation 43 Unit mm ...
Page 57: ...NKF 345 5 Installation 45 ...
Page 58: ...NKF 392C 5 Installation 46 ...
Page 59: ...NKF 393 5 Installation 47 ...
Page 60: ...NKF 394 5 Installation 48 ...
Page 61: ...NKF 396 5 Installation 49 ...
Page 84: ......
Page 85: ......