4-4
4-4 Shadow-sector countermeasure
4-4-1 Fore and aft directions
Setup without obstacle down to -5°.
4-4-2 Port and starboard directions
Setup without obstacle down to -15°.
4-4-3 Within radius 1m from EME
Avoid obstacles more than 2 degrees within 1m
in radius from EME.
Fig. 4-4-3
Minimum Requirement for EME Installation
based on
the GMDSS Performance Standards
Shadow-sector is generated when
some obstacle is exist in slashed part.
-5°
Shadow-sector is generated when
some obstacle is exist in slash part.
-15°