background image

 

3-8 

4. Following SSAS Schedule screen is displayed when correct password is entered. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 3.2.2c    SSAS Schedule screen (E-mail selected) 

5. Select SSAS Schedule you want to set from SSAS Schedule #1 to

5. 

6. Input Requesting Interval within the range of 0 to 99. 

7. Input LES number   

Input LES number to first box (from left) within the range of 000 to 063. 
Input LES number to second box (from left) within the range of 100 to 163. 
Input LES number to third box (from left) within the range of 200 to 263. 
Input LES number to fourth box (from left) within the range of 300 to 363. 

8. Select Network Type from following 7 choices. 

・ 

E-mail 

・ 

Telex 

・ 

PSTN 

・ 

Facsimile 

・ 

PSDN 

・ 

Closed Net 

・ 

Special Access 

9. Input Prefix Code within the range of 0 to 99.   

Summary of Contents for JUE-95SA -

Page 1: ...c co jp Telephone Facsimile e mail AMSTERDAM Branch Telephone Facsimile e mail 31 20 658 0750 31 20 658 0755 service jrceurope com SEATTLE Branch Telephone Facsimile e mail 1 206 654 5644 1 206 654 7030 marineservice jrcamerica com CODE No 7ZPSC0193 CODE No 7ZPSC0193 NOV 2012 Edition 3 JRC NOV 2012 Edition 3 JRC Not use the asbestos For further information contact URL http www jrc co jp JUE 95SA J...

Page 2: ......

Page 3: ...sat mini C Mobile Earth Station JUE 95SA Please read this manual carefully and carry out proper operation Please keep this manual importantly to refer when it is necessary Please use it when questions and troubles are caused in operation by any chance ...

Page 4: ...aler or agent you purchased or JRC branches Your communication data are transmitted via Inmarsat system and other global communications system so unusually some errors may occur in communication theory same as the landlines You are recommended to backup for your important data Usually digital scrambling of Inmarsat system protects your communication data privacy However you are recommended to unde...

Page 5: ...at improper handling poses a risk of causing injury or damage to the product and or assets Examples of symbols The symbol denotes DANGER WARNING or CAUTION The inside illustration of the symbol denotes meaning of the DANGER WARNING or CAUTION more concretely This example warns of possible electrical shock The symbol denotes prohibited action The inside illustration of the symbol denotes the specif...

Page 6: ...PAINT RADOME INMARSAT C EME MODEL NAF 742SA SERIAL NO MADE IN JAPAN C o m p a s s s a f e d i s t a n c e S t a n d a r d c o m p a s s 0 1 m S t e e r i n g c o m p a s s 0 1 m W A R N I N G DO NOT APPROACH UNDER TRANSMISSION RADIATION HAZARD Labels put on EME NAF 253SA Distances V S Radiation Levels Distance Radiation 0 5m 10W m2 0 3m 25W m2 0 2m 100W m2 ...

Page 7: ...F 742SA Label on IME Type2 EME NAF 742SA NOTES Attestation number which means safe high quality product and suits EU instruction Free circulation was permitted in the EU signatory Technological standard agreement proof and attestation number issued by Telecom Engineering Center Foundation in Japan R 001VZAA1011 ...

Page 8: ...ectrical shock or malfunction Ask maintenance and the adjustment of JUE 85 internal equipment to our sales department or nearest branch office Do not turn on the terminal under the primary power except the specific voltage mentioned below The primary power except the specific voltage may cause fire electrical shock or malfunction AC100V 220V 10 DC 24V 30 20 Do not check or repair the internal equi...

Page 9: ... because all units of EME are precision instrument Unwanted shock and force may cause malfunction Do not paint radome Painting of radome may cause decrease of the communication quality Ask our agency or office to abandon JUE 95SA EME When the lithium battery is short circuited receives the impact or it gets wet because of water it causes generation of heat the explosion and the ignition if this is...

Page 10: ...ly Unit FFA Forum Fisheries Agency IME Internally Mounted Equipment IMO International Maritime Organization INMARSAT INMARSAT Ltd ISPS International Ship and Port Facility Security JB Junction Box MES Mobile Earth station PSU Power Supply Unit SOLAS Safety of Life at Sea SSAS Ship Security Aleart System VMS Vessel Monitoring System ...

Page 11: ...8 2 7 2 4 2 DTE Display NDZ 227 Keyboard NDF 369 2 7 2 4 3 Printer NKG 800 2 8 2 5 Configuration JUE 95SA Standard components 2 9 2 5 1 EME NAF 742SA 2 9 2 5 2 EME NAF 253SA 2 10 2 5 3 IME NTF 782SA 2 11 2 5 4 JB MPBC40613 2 12 2 5 5 Security Button NQE 3154 2 13 2 5 6 EXT PSU NBD 577C 2 14 2 5 7 Coaxial Cable CFQ 5924A3 CFQ5924A15 2 15 2 6 Optional Equipment Dimensional drawing 2 16 2 6 1 DTE Dis...

Page 12: ...ransmission 3 18 CHAPTER 4 MAINTENANCE 4 1 4 1 Maintenance 4 1 4 2 Daily maintenance 4 1 4 3 Troubleshooting 4 2 4 4 Shadow sector countermeasure 4 4 4 4 1 Fore and aft directions 4 4 4 4 2 Port and starboard directions 4 4 4 4 3 Within radius 1m from EME 4 4 4 4 4 Reference Estimation methods of RX TX signal loss by physical obstructions 4 5 4 5 Noise countermeasure interference with other equipm...

Page 13: ...d the gross tonnage 500 tons or more that engaged it in the international voyage by the ISPS code of SOLAS the agreement Chapter XI 1 XI 2 ship and harbor equipment ISPS code JUE 95SA can fill the demanded function of the SSAS of the below mentioned documents 1 SOLAS Chap XI 2 Regulation 2 6 2 ISPS Code Part A 9 4 18 3 IMO MSC Resolution 136 76 147 77 4 IMO MSC Circ 1072 1073 ...

Page 14: ...1 2 ...

Page 15: ...r Security buttons can be connected to the Junction Box CHAPTER 2 Configuration 2 1 Cable connection and example of setting PSU Printer Captain Room Other Rooms Bridge Fig 2 1 JUE 95SA Installation wiring diagram Security Button Security Button Security Button IME JB Security Button DTE TTYCS 1Q or equivalent EME Option Option Option Option ...

Page 16: ...arts for Installation by JRC for IME 7ZXSC8501 1 JUE 95SA Instruction Manual 7ZPSC0193 1 JUE 95SA Operation Guide 7ZPSC0211 1 SSAS Setup Tool CD ROM 7YZSC0005 1 Optional Components Security Button NQE 3154 Max 2 DTE Data Terminal Equipment NDZ 127C1 NDZ 227 1 Keyboard NDF 368 NDF 369 1 Printer NKG 800 1 DTE Signal Cable 1 5m 7ZCSC0203 1 DTE Power Cable 2m 7ZCSC0204 1 Printer Signal Cable 1 5m 7ZCS...

Page 17: ...5SA Standard components appearance 2 3 1 EME NAF 742SA NAF 253SA The EME is installed above deck for receiving signals from satellites The EME is covered with a radome Fig 2 3 1a EME NAF 742SA Fig 2 3 1b EME NAF 253SA ...

Page 18: ...5 for SB1 2 X6 for SB3 4 6 RECEIVE lamp 2 POWER lamp 3 SYNC lamp 5 TRANSMIT lamp 1 POWER switch 4 LOG IN lamp 7 ALARM lamp 8 RESET button 9 TEST button 2 3 2 IME NTF 782SA The IME is installed below deck Fig 2 3 2a IME Front view Fig 2 3 2b IME Rear view 2 PSU connecter ...

Page 19: ...2 5 2 2 3 3 JB MPBC40613 It can be mounted to bottom part of IME Fig 2 3 3 JB 2 3 4 Security Button NQE 3154 Fig 2 3 4 Security Button ...

Page 20: ...2 6 2 3 5 EXT PSU NBD 577C Fig 2 3 5 EXT PSU 2 3 6 Coaxial cable CFQ 5924A3 or CFQ5924A15 It connects EME and IME Fig 2 3 6 Coaxial Cable ...

Page 21: ...2 7 2 2 4 Optional components appearance 2 4 1 DTE Display NDZ 127C1 Keyboard NDF 368 Fig 2 4 1 DTE NDZ 127C1 2 4 2 DTE Display NDZ 227 Keyboard NDF 369 Fig 2 4 2 DTE NDZ 227 and Keyboard NDF 369 ...

Page 22: ...2 8 2 4 3 Printer NKG 800 Fig 2 4 3 Pinter ...

Page 23: ...2 9 2 2 5 Configuration JUE 95SA Standard components 2 5 1 EME NAF 742SA Fig 2 5 1 EME NAF 742SA FWD Unit mm Mass Approx 1 5kg ...

Page 24: ...2 10 2 5 2 EME NAF 253SA Fig 2 5 2 EME NAF 253SA Unit mm Mass Approx 2 4 kg Color N9 ...

Page 25: ...2 11 2 2 5 3 IME NTF 782SA Fig 2 5 3 IME Unit mm Mass Approx 1 3kg ...

Page 26: ...2 12 2 5 4 JB MPBC40613 Fig 2 5 4 JB Unit mm Mass Approx 1 1kg ...

Page 27: ...2 13 2 2 5 5 Security Button NQE 3154 Unit mm Mass 0 35kg Fig 2 5 5 Security button NQE 3154 54 80 MADE IN JAPAN 24 4 φ4 5 12 12 54 80 55 30 ...

Page 28: ...e plug P1 to suitable receptacle according to the input voltage 2 Stick the attached label for voltage indication on the name plate according to the input voltage Specification Input voltage AC 100 220V typical 10 50 60Hz typical Single phase DC 24V typical 30 20 Output voltage DC 24V Unit mm Mass Approx 5 4kg ...

Page 29: ...2 15 2 2 5 7 Coaxial Cable CFQ 5924A3 CFQ5924A15 Type Length Mass CFQ5924A15 15m 0 5m Approx 1 4kg CFQ 5924A3 30m 1 0m Approx 2 3kg Minimum bending radius 46mm Fig 2 5 7 Coaxial Cable Unit mm ...

Page 30: ...2 16 4 Ø4 5 round hole 4 Ø4 8 0 round hole 2 6 Optional Equipment Dimensional drawing 2 6 1 DTE Display NDZ 127C Fig 2 6 1 DTE Display NDZ 127C1 Unit mm Mass Approx 4 5kg ...

Page 31: ...2 17 2 2 6 2 DTE Keyboard NDF 368 Fig 2 6 2 DTE Keyboard NDF 368 Unit mm Mass 0 4kg ...

Page 32: ...2 18 2 6 3 DTE Display NDZ 227 ...

Page 33: ...2 19 2 2 6 4 DTE Keyboard NDF 369 Fig 2 6 4 DTE Keyboard NDF 369 Unit mm Mass 0 4kg ...

Page 34: ...2 20 Fixing Fix the printer on the desk with the hook and loop fastener attached to the printer base Unit mm Mass Approx 3 7kg 2 6 5 Printer NKG 800 Fig 2 6 5 Printer ...

Page 35: ...Before security alert transmission set the destination message and so on in the setting menu Refer to clause 3 2 3 1 4 Transmission of Security Alert In case of security alert transmission press security button After 30 seconds security alert is transmitted Security alert is transmission on a setup interval until canceled Refer to clause 3 3 All LEDs are turned off due to JUE 95SA changed its stat...

Page 36: ... below S F message communication Telex Facsimile Data and E mail Data Reporting Polling Position Call Log and Alarm pack Message Editor File Management Receiving Message Management Inmarsat C EGC Call Logging Initial Setting NCS LES Preferred Ocean Region e t c Testing function PV test Alarm pack ROM version e t c Warning message 3 1 8 Optional Printer When the printer is connected to JUE 95SA ref...

Page 37: ...d even if the button is pushed when the bad connection cannot be recognized Normal condition To extinction the lamp turn on and off the power switch 1 TX Alarm informs some sort of malfunction is occurred on communication devices 2 Battery Alarm informs the battery is decreased to under the specified level Table 3 1 2 Function of switch and buttons Name Function Remarks 1 POWER Switch Power ON OFF...

Page 38: ...on MENU LIST Then below mentioned screen is displayed Fig 3 2 1a Scheduled Transmission screen 2 Press Ctrl F10 key after the data of Scheduled Transmission is displayed on Scheuled Transmission screen 3 Below mentioned window is displayed Then enter 4 digit password and click SET button 4 Below mentioned SSAS Schedule screen is displayed when correct password is entered Fig 3 2 1b Input Password ...

Page 39: ...e you want to set from SSAS Schedule 1 to 5 6 Confirm below mentioned data on above screen Requesting Interval LES Destination Code Subscriver s No Network Type E Mail Telex PSTN Facsimile PSDN Closed Net Special Access Security Alert ON OFF SSAS Message Charactor Code ...

Page 40: ...of menu bar and open the dialogue box of COM PORT then click OK and confirm that COM PORT is opened normally 2 Confirm that COM PORT of PC and PORT of IME is connected with serial cable 3 Confirm INMARSAT terminal works normally or not by seeing the ligtning of POWER LED of IME 2 Operation except Exit Display and Ver is not available during winIST is communicating with INMARSAT terminal the functi...

Page 41: ... Scheduled Transmission screen is opened Fig 3 2 2a Scheduled Transmission screen 2 Press Ctrl F10 key after the data of Scheduled Transmission is displayed on the screen 3 Following window is displayed Then enter 4 digit password and click SET button Fig 3 2 2b Input Password screen ...

Page 42: ...Input LES number Input LES number to first box from left within the range of 000 to 063 Input LES number to second box from left within the range of 100 to 163 Input LES number to third box from left within the range of 200 to 263 Input LES number to fourth box from left within the range of 300 to 363 8 Select Network Type from following 7 choices E mail Telex PSTN Facsimile PSDN Closed Net Specia...

Page 43: ...a into INMARSAT terminal when setup is completed When Telex is selected to Network Type 9 Input Destination Code and Subscribers Number Input Destination Code to first box from left within the range of 0 to 999 Input Subscribers Number to second box from left by 11 digit figure 10 Select Character Code from following 2 choices IA5 ITA2 11 Setup Security Alert ON OFF 12 Input SSAS Message by one by...

Page 44: ... Code to first box from left within the range of 0 to 999 Input Subscribers Number to second box from left by 12 digit figure 10 Select Character Code from following two choices IA5 DATA 11 Setup Security Alart ON OFF 12 Input SSAS Message by one byte character 512 character or less 13 Repeat the procedure from No 5 to No 12 when you edit other SSAS Scheduled data 14 Click SET button to write the ...

Page 45: ...ering below mentioned Responses means number 1 to 5 of SSAS Schedule Error Please set SSAS Schedule Requesting Interval data from 1 to 99 Response Setup the setting value of Requesting Intertval of SSAS Schedule within the range of 1 to 99 Fig 3 2 2f LES1 data setup error window Error Please set SSAS Schedule LES1 data from 000 to 063 Response Set the LES No to first box from left of SSAS Schedule...

Page 46: ... 163 Fig 3 2 2h LES3 data setup error window Error Please set SSAS Schedule LES3 data from 200 to 263 Response Set the LES No to third box from left of SSAS Schedule within the range of 200 to 263 Fig 3 2 2i LES4 data setup error window Error Please set SSAS Schedule LES4 data from 300 to 363 Response Set the LES No to fourth box from left of SSAS Schedule within the range of 300 to 363 NOTE ...

Page 47: ...riber s number into second box from left by 11 digit figure or less when Network Type is Telex by 10 digit figure or less when Network Type is PSDN by 12 digit figure or less when Network Type is PSTN by 5 digit figure or less when Network Type is Closed Net or by alphanumeric character 6 character or less when Special Access or E mail is selected Fig 3 2 2l Modem Type data setup error display Err...

Page 48: ... 2 2o Data setup failure window In this case carry out following procedure and do the setup again 1 Click Setting of menu bar and open the dialogue box of COM PORT then click OK and confirm that COM PORT is opened normally 2 Confirm that COM PORT of PC and PORT of IME is connected with serial cable 3 Confirm INMARSAT terminal works normally or not by seeing the ligtning of POWER LED of IME 5 Opera...

Page 49: ...FF status Push once ON Status Push again OFF Status Transmission start Transmission cancel Security transmission causes no reactions of terminals No LED lit and buzzer does not sound on the IME no communication status is displayed on DTE optional component and nothing is printed on the Printer optional component NOTE Button Button cover NO Push Security button ON Is the button depressed again with...

Page 50: ...nsmission Push the Button again after 30 seconds passed Security Alert is transmitted only of first time and no transmission is carried out after then Pull out the Power cable from IME rear panel and push the button to turn to OFF when you want to discontinue transmitting at once regardless of the time after the button is pushed NOTE The message of the following content reaches the destination whe...

Page 51: ...tton The button starts to light Test transmission of Security Alert is started Test transmission of Security Alert is completed Push Security button ON Test button starts to blink Push Test button again Light disappears Pushed Security button OFF Test button stops blinking Still lighting Means user s action Means status Security button Is the button depressed again within 30 seconds ...

Page 52: ...ecurity button certainly Security Alert transmission is not canceled as long as one button is remained turned on NOTE Time required until completing Test transmission Transmission setting number 1 5 minutes 2 17 minutes 3 29 minutes 4 41minutes 5 53 minutes The time required is done back and forth according to the state of the line and the message length etc NOTE Confirm all of security buttons ar...

Page 53: ...ur specialized maintenance persons may cause fire or abnormal operation of this equipment or electrical shock for you This equipment meets the technical standard of the Ministry of Internal affairs and Communications MIC Do not adjust the internal circuit or exchange the parts because the internal circuit is adjusted strictly When an abnormal operation is found please contact to our sales departme...

Page 54: ... direction IME Exchange YES EME Exchange YES YES YES YES NO NO NO NO NO NO Confirm again with setting of correct Ocean Region NO Confirm the type of EME and IME EME NAF 742SA NAF 253SA IME NTF 782SA Is it turned to light after 20 seconds Is Only SYNC lamp blinking and all other lamps are lighting Is PSU normal Continued to next page NO Is there any blocking Is the Ocean Region setting is incorrect...

Page 55: ...exchange Blinking with 2 0 seconds intervals Security button error Confirm cable of Security button Confirm Dip switch of IME Exchange Security button Lighting Two or more events are occurred in same time Confirm above 3 items Fig4 3b Troubleshooting Flowchart 2 2 NO YES NO YES NO Does Buzzer sounds during operation EME internal GPS error Completed From previous page Is ID registered ID Applicatio...

Page 56: ...stacle down to 15 4 4 3 Within radius 1m from EME Avoid obstacles more than 2 degrees within 1m in radius from EME Fig 4 4 3 Minimum Requirement for EME Installation based on the GMDSS Performance Standards Shadow sector is generated when some obstacle is exist in slashed part 5 Shadow sector is generated when some obstacle is existed in slash part 15 ...

Page 57: ...acle R m ii Estimate the effective diameter d of the obstacle d m iii Read off the loss LB in the Chart I LB dB iv Determine whether the loss LB is allowable Chart 4 4 4b The Loss Due to cylindrical obstacle d 0 2m Pole or Mast R 5m Example i R 5 ii d 02m iii LB 1dB approx iv Allowable Fig 4 4 4a EME Installation against cylindrical obstacle Under lower elevation angle area sometimes the communica...

Page 58: ...iii Estimate the obstacle area SB just occupying effective propagation radius see hatched area shown in Example 2 SB dm2 iv Read the loss in the Chart II 2 LB dB v Determine whether the loss is allowable Chart4 4 4c Effective Propagation Radius vs Obstacle s Distance SB 0 5m r 1m Effective Propagation radius R 5m Radar mast Example i R 5m ii r 1m iii SB 0 5m2 iv LB 1dB approx v Allowable Fig 4 4c ...

Page 59: ... 4 Chart 4 4c The loss due to un cylindrical obstacle When the satellite is existed under lower elevation angle area sometimes the communication might be impossible due to fading or weather condition NOTE ...

Page 60: ...her equipment Earthing of EME antenna is highly recommended when trouble is caused in transmission noise interference e t c due to occurrence of interference with other communication device Fig 4 5 Earthing of EME antenna Earth bolt MTL318538A Option ...

Page 61: ... by the tip of narrow object like extended clip φ0 5mm Push until you feel the object clicks refer Fig 4 6 Five lamps POWER lamp to RECEIVE lamp lights in order and starts blinking it will takes approximately 10 seconds Turn on POWER switch with confirming these lamps are blinking The data which are received message call logging history and alarm history memorized in IME are cleared when RESET but...

Page 62: ...d wet it to water There is danger of exploding 4 7 2 When ordering repair When a failure has been detected check it according to the Trouble shooting described in this manual When abnormalities are still accepted stop operation and contact the purchasing dealer JRC agent or one of the JRC branches In the case of fixing during the term of a guarantee When it breaks down in the state of the normal o...

Page 63: ...which you purchased the device or one of our marketing offices for overhaul apart from daily services In this case it becomes charged Disposal of packaging material When disposing packaging material follow the rules of the pertinent local government CAUTION Ask JRC to abandon JUE 95SA EME When the lithium battery is short circuited receives the impact or it gets wet because of water it causes gene...

Page 64: ...4 12 ...

Page 65: ...W EME and IME RX 15 W EME and IME Environmental Condition Ambient temperature 35 C 55 C EME operational 15 C 55 C IME operational Preservation temperature 40 C 80 C EME NAF 742SA 40 C 75 C EME NAF 253SA Relative humidity 95 40 C Ice 25 mm EME Precipitation 100 mm hour EME Velocity 100 knots Vibration IEC60945 compatible Coding Interleaved convolutional code R 1 2 K 7 Data rate Transmission 600 bps...

Page 66: ...5 2 ...

Page 67: ...ealer from which you purchased the device or our marketing offices that is nearest to you for any question as to the after sales service JRC Tokyo Japan http www jrc co jp JRC Amsterdam http www jrceurope com JRC Seattle http www jrcamerica com JRC web site ...

Page 68: ...6 2 ...

Page 69: ......

Page 70: ...c co jp Telephone Facsimile e mail AMSTERDAM Branch Telephone Facsimile e mail 31 20 658 0750 31 20 658 0755 service jrceurope com SEATTLE Branch Telephone Facsimile e mail 1 206 654 5644 1 206 654 7030 marineservice jrcamerica com CODE No 7ZPSC0193 CODE No 7ZPSC0193 NOV 2012 Edition 3 JRC NOV 2012 Edition 3 JRC Not use the asbestos For further information contact URL http www jrc co jp JUE 95SA J...

Reviews: