PAGE 9
SCENECONTROL 100 OPERATING INSTRUCTIONS
pushing and holding a GO button, and switch to the Status page while the winch is in motion. Make sure that a
spotter is watching the piece while you watch the screen!
PARAMETER PAGE
From a winch base screen, the PARAM PAGE touchbutton opens the parameter page for that winch.
The parameter page displays certain winch
values, and provides a place where an
authorized user can manipulate them. The
BASE PAGE jump button at the bottom left of
the screen will return to the winch base screen.
Design, Manufacture and Installation of Theatrical Equipment Worldwide
(315) 451-3440
Fax (315) 451-1766
www.jrclancy.com
Rev 3: October 7, 2009
value to
The user will automatically log off
following their descriptors:
is loaded into the SPEED field when the base
s. If the selected winch speed is less
s. If the winch is
aveling at less than full speed, it will require proportionately less time to decelerate to a stop.
Values displayed on this page are password-
protected. Certain crucial values are protected
by the system level password. These are
indicated by and (S) following their descriptor.
Other values have the indication (U) following
their descriptor. These values may be
adjusted by an operator logged in with the
User level username and password. If an
operator is not logged in, touching a numeric
entry field will pop up the user name and
password entry fields. To enter the user name,
touch the user name field; an alphanumeric keypad will appear. Use this to key in the appropriate user name,
then press the ENTER key on the keypad. Follow the same procedure in the password field to enter the
password. When these values are entered, the display returns to the winch parameter page. Once the access
privileges have been activated, touching an appropriate entry field will bring up a keypad to permit a new
be entered.
The LOG OFF button is used to log the user off after changing parameters.
after five minutes, to prevent unauthorized access to parameters.
User-level privileges permit changes to the following items, indicated by a (U)
SUL: Height of the batten above the reference point at the Soft Upper Limit
SLL: Height of the batten above the reference point at the Soft Lower Limit
DFT SPD: (Variable-speed winches only) The default speed that
screen is opened, or when the DFLT SPD touchbutton is pushed.
ACC: (Variable-speed winches only) Time (in milliseconds) for the winch to accelerate to full speed. As an
example, with a setting of 3000 the winch will reach full speed in 3 second
than full speed, it will require proportionately less time to reach that speed.
DEC: (Variable-speed winches only) Time (in milliseconds) for the winch to decelerate from full speed to a stop.
A setting of 3000 will cause the winch to decelerate from full speed to a stop in 3 second
tr