III.

 

CHARACTERISTICS 

Operating Range 

 

0+40°C 0-90%RH non-condensing 

Storage temperature

 

0 + 80°C 

Number of Input (connector) 

1 Digital or 4 Digital / Analog 

Number of channels 

2 or 4 

Input types 

Digital/PT100/PT1000/4-20mA/0-1V/ ON-OFF mixable 

PT100 input 

measurement range: 
resolution:  
accuracy (without probe):   

 

 
-200°C to +300°C  (*) 
0,01°C 
± 0,1°C from  -20°C to +60°C 
±0,2°C from  -100°C to -20°C and from +60°C to +200°C 
± 0,5°C beyond  

Digital T input 

measurement range: 
resolution:  
accuracy - standard probe: 
accuracy  - probe for incubators: 
accuracy - low T° digital sensor: 

Depending on the type of probe (SPY RF range) 
-40 +85°C / -200 – 0°C (Low T° digital sensor) 
0,1°C / 0,01°C (Low T° digital sensor) 
±0.3°C from -20°C to +30°C and ±0.5°C outside 
±0.2°C from +35°C to +46°C 
±0.2°C from -20°C to 0°C and ±0.5°C outside 

TH Metal digital input (=2 channels) 

Temperature: 

  Measurement range: 
  resolution:  
  exactitude (probe alone): 

Humidit

y: 

  Measurement range: 
  resolution :  
  accuracy (probe alone): 

 
 
- 40°C to +85°C  
 0,01°C 
 

±

 0,2°C (from -20°C to +50°C) 

±

 0,4°C outside 

 
0 à 100% 
0,01% 

±

2% (from 20% to 80%)  ±3,5%  outside 

Current input 0-20 ou 4-20 mA 

measurement range: 
resolution:  
accuracy (SPY IP alone): 

 
0 to 20 mA or 4-20mA 
0,001 mA 
± 0,01 mA 

Voltage input 0-1V 

measurement range: 
resolution:  
accuracy (SPY IP alone: 

 
0 to 1000 mV   
0,1 mV 
0,5 mV 

Frequency input 

Measurement range: 

             resolution:  
             accuracy (SPY IP alone): 

 
0 to 500 Hz 
0,5 Hz 
± 1 Hz   

Impulse input  

measurement range: 
resolution:  

 
0 to 32 767 

ON/OFF input 

Dry contact or  0-3.3V max 

Logging interval 

15’ 

(minimum recommanded)

 to 90 min 

Memory Size 

10 000 measurements per channel 

Power supply

 

 

9V DC 650mA or via Ethernet (POE) 

Backup battery

 

Battery life

 

 

Ni-MH 3.6V – 730mA 
From 4 to 6h  

Dimensions 

153 x 82 x 35mm 

IP Classification

 

IP20 

IK Classification 

IK03 

Protection 

Internal fuse 125V – 1A** 

Compliant with DBT 2004/108/CE 
Compliant with DBT 2006/42/CE 

EN 61326-1 (July 2006) 
EN 61010 (January 2011)  

(*) depending on the type of probe   (**) replacement by return of the unit to the factory 

Summary of Contents for SPY IP 4

Page 1: ...USER MANUAL SPY IP 10486F...

Page 2: ...Start modes 10 c Zone 4 Alarm Thresholds 10 d Zone 5 Off Modes 10 e Main Menu 10 4 BACKLIGHT COLOURS 10 5 SCREEN NAVIGATION 11 a Main menu 11 b Menu Configuration 11 c Device Status Menu 12 d Alarm M...

Page 3: ...omplies with current regulations CE MARKING this device complies with EU legislation for electric security inflammability disturbing radiation emission and immunity to surrounding electric disturbance...

Page 4: ...guration information from the DHCP server If the UDP broadcast is not allowed you must carry out a manual installation on Sirius Storage using the IP address provided by the DHCP server and the serial...

Page 5: ...twork UDP packets are never transmitted and you must carry out a manual installation If the manual installation fails make sure that the internal serial number matches the serial number printed on the...

Page 6: ...3 Declare in Sirius measures RH on channels 2 and or 4 c Identification of the connectors d Wiring Rear view of the connectors Probe 1 to 4 Ethernet Network RJ45 Modular connector Male plug end on the...

Page 7: ...JRI recommends using the cable with the reference number 00949 for connecting equipment which is not provided with a compatible socket f Battery backup Minimum battery backup time is 6 hours with a 3...

Page 8: ...e alone Humidity Measurement range resolution accuracy probe alone 40 C to 85 C 0 01 C 0 2 C from 20 C to 50 C 0 4 C outside 0 100 0 01 2 from 20 to 80 3 5 outside Current input 0 20 ou 4 20 mA measur...

Page 9: ...avoid damaging the touchscreen do not use sharp instruments and do not press hard 2 Touchscreen Description Channel ID Status of the device Measurement and start modes Channel number and alarm thresh...

Page 10: ...resholds High Pre Alarm High Alarm Low Pre Alarm Low Alarm d Zone 5 Off Modes Push Button Programmed stop delay Target value upward movement Target value downward movement e Main Menu Back to previous...

Page 11: ...r a pencil tip See Principle above Press the screen to access the main menu Back to measurement display a Main menu Select the desired zone by pressing the relevant icon b Menu Configuration The SPY I...

Page 12: ...dgment from the touchscreen Spy IP The action will be authorized and stored by Sirius The password change will just be made from Sirius Default IP Spy has 1 Profile Administrator mdp 1111 V HOW THE SP...

Page 13: ...mmed via Sirius are Immediate Pushbutton Programmed start delay Target value Change of state of one of the other channels a Immediate default mode in Sirius The channels set with this start mode will...

Page 14: ...art recording when it has reached its target value taking into account the direction of the variation upward or downward movement If a channel has no target value it is considered as being configured...

Page 15: ...t got the rights the request will be rejected and the channel will continue recording d Target value This off mode can only be used and configured channel by channel The channel will stop recording w...

Page 16: ...re alarm then the backlight colour will be the same for all the channels according to the most important even In this case it will be RED The threshold alarms can be either instantaneous or continuous...

Page 17: ...hout prior notice IX MAINTENANCE CONTRACT With our maintenance contract you will benefit for a minimal period of 2 years from the following advantages material verification once or twice a year warran...

Reviews: