KIROVETS K-744R1, K-744R2, K-744R3, K-744R4 tractors
85
4.12 ENGINE START-UP FROM EXTERNAL POWER SUPPLY
If the engine cannot be started from storage batteries due to their discharged state, it is per-
mitted to start the engine from an external power supply of from storage battery of another
tractor.
CAUTION!
In case of engine start-up from storage battery of another tractor, it is
necessary to strictly obey the following rules:
1. Start the engine up with switched off battery master switch of the tractor, which en-
gine is to be started from an external power supply. It is necessary to switch on the
battery master switch immediately upon the start of a steady operation of the engine
being started.
2. Engine of the tractor, which accumulator is used as an external power supply, shall
be shut off.
A failure to obey these rules can lead to increased discharge of storage battery
of the vehicle, from which the start-up is performed, or to a failure of its genera-
tor.
4.13 HVAC SYSTEM OPERATION
The system can be operated in the mode of ventilation, heating and air conditioning.
Ventilation
To perform forced air supply to the cabin,
switch the fan (handle 8) on to position
1, 2 or 3.
Fig. 23 Fuel pump reducing valve
1
– fuel line bolt; 2 – rotating angle joint;
3, 8, 9, 13
– O-rings;
4
– union; 5, 7 – nuts; 6 – adjustment screw;
10
– spring; 11 – ball; 12 – fuel pump casing; 14 – spacer; 15
– fuel pump cover.