Introduction  

The  JSD  TestPhone  AM5  Tone  Amplifier  product  provides  a  means  of  tracing  the 
audible signal generated by the TG5 Tone Generator product across a copper cable 
network.  The  product  features  five  (5)  sensitivity  levels  with  selectable  band-pass 
filtering  and  either  contact  or  inductive  pickup  of  the  audible  signal  which  is 
amplified  and  reproduced  on  the  internal  loudspeaker  or  external  Headset.  Digital 
signals  [25-250kHz]  present  on  the  copper  cable  network  are  also  identified  and 
indicated with both audible and visual indicators. The product also features ‘qTrace’ 
technology  which  allows  the  individual  discrimination  and  visual  indication  of  up  to 
four ‘qTrace’ tones. 

 

Powering `ON` the Probe 

The AM5xs is switched 

`on`

 by pressing the [

ON/OFF  SENS+

button  for  two  (2)  seconds,  whereupon  a 

BEEP

  will  be 

generated,  the  amplifier  is  switched  on  at  the  maximum 
sensitivity level and the 

‘ON LO BAT’

 indicator will flash slowly.  

 
Normal Tone Tracing (Audio Indication)

 

To trace the tone bring the probe tip close to the wire and listen 
for the tone being reproduced in the loudspeaker. 
 

Band Pass Filter

 

To  activate  the  internal  band  pass  filter  (attenuating  signals 
below  800Hz  and  above  1500Hz)  switch 

`on`

  the  AM5xs  by 

pressing  the  [

ON/OFF  SENS+

]  button  for  two  (2)  seconds  and 

continue  holding  the  button  for  a  further  three  (3)  seconds  (5 
seconds  in  total).  Confirmation  of  the  activation  will  be  the 

‘ON 

LO  BAT’ 

indicator  flashing  fast.  To  deactivate  the  band  pass 

filter switch the AM5xs 

`off`

 

 

`qTrace` Tone Tracing (Visual Indication) 

 

Trace the signal by bringing the probe tip to within 100mm of the 
wire  and  observing  the  ‘

qTrace

’  indicators  on  the  AM5xs.  A 

maximum of four (4) ‘

qTrace

’ tones may be identified.  

This function will be particularly useful when used in conjunction 
with a number of TG5xs units to identify individual pairs.  

 
Range 

 

The  AM5xs  will  detect  a  standard  tone  generated  from  the 
TG5xs at 12 miles and q Trace Tones at up to 15 miles.  

 
Sensitivity 

 

The  AM5xs  is  switched  on

 

at  maximum  sensitivity  level.  The 

sensitivity  may  be  reduced  by  momentarily  touching  the  [

ON/

OFF  SENS+

]  button.  There  are  five  levels  of  sensitivity  before 

the  unit  will  revert  to  the  highest  setting.  To  prevent  distortion, 
only use a level adequate to hear the tone. 