Operating controls 

 

 
 
 
 
 

o

  Start fan by pressing button 1 on control panel 

o

  Increase or decrease speed by pressing buttons 2 or 4 (maximum 5 speed) 

o

  When the timer button 5 is pressed for 2 seconds, timer function will be on for 15 

minutes. 

o

 

When the aluminium filter is “dirty”, the warning is given by displaying the letter 

C

 on 

the display panel. When the filters are cleaned, dried and re-fitted, button 1 should be 
pressed for 3 seconds when the product is off to clear the 

C

 letter on the display panel. 

The letter

 E

 will appear on the display and the product will start working again as 

normal. 

o

  If you want to continue using your hood without deleting the letter 

C

 on the display, the 

active speed number will appear for 1 second when you first start the hood and then 
the 

C

 will appear with the hood running as normal. 

o

  Please note that the letter

 C

 will appear after 60 hours 

o

  Warning 

– do not attempt to clean the carbon filters. These must always be replaced. 

o

  Remote control can be used instead of touch control (only on RC models). 

 

 
A = Motor on or off 
B = Increase Speed 
C = Decrease Speed 
E = Lights on or off 

 

 
 

Troubleshooting Chart 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

 
 

 
 
 
 
 
 

 

Check 

electrical 

connections. 

Voltage 

should be 

220v and 

must be 

earthed 

Check Motor 

switch. 

Motor switch 

must be in 

“on” position 

 

Check 

batteries in 

remote if 

applicable 

Check 

lamp 

switch. 

Lamp 

switch 

should 

be in 

“on” 

position 

Check outlet 

chimney (air 

outlet must 

be open 

Check 

the 

bulbs 

are 

working 

Check 

Aluminium 

filter 

– 

Aluminium 

filter cassette 

should be 

washed

 

monthly 

Extractor is 

not working 

Extractor 

lamp is not 
illuminated 

Extractor not 

venting to 

outside 

Extractor gives 

poor suction 

Check 

the 

fuse on 

control 

board 

Change 

fuse for 

1 amp. 

 

1        2         3       4       5       6 

 

Letter “c” 

Displayed 

Summary of Contents for 3173-90-IX

Page 1: ...TALLATION MARCH 2013 WWW JSI UK COM Page 1 of 9 Cooker Hood Range Model JSI 3173 90 IX Please read fully before installation or use May 2012 Version 2 English UK Installation Instructions User Guide Warranty Information ...

Page 2: ...re a repair within the manufacturing guarantee period please call 01759 487822 Your JSI appliance comes with a 12 month guarantee Please REGISTER your appliance online at www warrantysolutions co uk jsi You also have the option to EXTEND YOUR WARRANTY to a full 3 years or 5 years parts and labour ...

Page 3: ...EEE Directive and the subsequent European Parliament and Council Directive 2003 108 EC that amended the WEEE Directive As a result JSI UK pay a proportion of the purchase cost to ensure that collection of the equivalent weight of household appliances are disposed in accordance with these regulations when purchased through a retailer or trade supplier JSI UK is a member of the EXEL Europe WEEE comp...

Page 4: ...rheated oil and fat could set the cooker hood on fire Do not use the cooker hood without the grease filters in place Ensure that filters are changed as appropriate Safety of Children This appliance is not suitable for use by young children The use of the appliance should be explained to older children to enable them to use it safely Packaging should be kept out of reach of babies and young childre...

Page 5: ...detergent Avoid alkaline dishwasher detergents of pH greater than 7 Let the filters dry fully before replacing them B Carbon Filters If the cooker is connected for re circulation a carbon filter must be fitted These can be purchased from your supplier or on www jsi uk com Product Code YT971 1000 05 These carbon filters should be replaced when indicated on your cooker hood if it has a filter replac...

Page 6: ...re the bracket is level using a spirit level but note The bottom of the motor block is fixed at point shown 5 Insert the 8mm wall plugs into holes A B C 6 By using the 3 9 x 22mm screws provided screw the chimney mounting to the 0 6mm wall plugs Figure 4 7 Insert the hood suspension screws by screwing the 5 5 x 45mm screws into the 8mm wall plugs at position A and B but leave these loose with appr...

Page 7: ...ct through an outside wall In the case of use in re circulating mode addition carbon filters will be required not supplied The product code for the correct charcoal filters for this model is JSI 90001 These filters remove a large amount of smells that recirculate within the cooking environment Aluminium Grease Filters These are supplied with your product and the appliance should never be operated ...

Page 8: ... 1 second when you first start the hood and then the C will appear with the hood running as normal o Please note that the letter C will appear after 60 hours o Warning do not attempt to clean the carbon filters These must always be replaced o Remote control can be used instead of touch control only on RC models A Motor on or off B Increase Speed C Decrease Speed E Lights on or off Troubleshooting ...

Page 9: ...rmation JSI UK Limited Sherston Wiltshire United Kingdom SN16 0LW TECHNICAL SPECIFICATIONS Size Options 60cm 90cm 90cm 100cm 110cm and 120cm wall mounted Construction and Finishes Stainless Steel INOX 430 grade Brushed Steel and Black finishes Motor Power Input Steel fan housings 240w 800 m h Power input 210w Sound rating dbA Setting 1 48 Setting 2 52 Setting 3 55 Setting 4 57 Setting 5 61 Output ...

Reviews: