10
REMOVING & REPLACING FILTERS:
To Remove the Filters:
Rotate the rear of each filter upwards by 30° until compression is lost, then pull away from the motor housing.
To Replace the Filters:
Ensure that the filter and motor housing mating faces are clean; do not allow any dust or foreign objects to fall into the
motor housing.
Align arrows on filter and motor housing, press filter into place and rotate until a click is heard/felt. Recheck airflow before use.
(See
Battery and Airflow Check
).
If the filters are not fitted correctly, filtering efficiency will be severely reduced.
Each filter is fitted with a
pre-filter housed within a protective cover. Pre-filters prolong the life of the main filters by trapping larger particles. The pre-filters can be replaced
from within the protective covers as
required. Dispose of used filters in accordance with local legislation.
REMOVING & REPLACING PRE-FILTERS: (Always replace both pre-filters simultaneously)
1.
Locate the tab at the rear of the pre-filter cover and lift it to begin freeing the cover.
2.
Release the two remaining hooks from under the front of the main filter case lid to release the cover from the main filter body.
3.
Pull the pre-filter out from under the three locating hooks. Dispose of used pre-filters in accordance with local legislation.
4.
Clean the pre-filter cover using a damp cloth and/or soft brush, then feed a fresh pre-filter underneath the three locating hooks.
Ensure the
correct orientation of the pre-filter pad in the cover.
5.
Clip the pre-filter cover back onto the filter, locating the curved front edge first.
6.
Snap the rear clip into place over the rear of the filter case lid.
1
2
3
1
4
5
1
6
HOOKS
PRE-FILTER
30°
30°
TAB
Summary of Contents for Powercap Infinity
Page 2: ...EN 3 FR 20 DE 38 NL 56 DA 74 NO 92 SV 110 FI 128 ES 146 PT 164 IT 182 TR 200 PL 218 CS 236...
Page 254: ...254...