7 Setting up a Transmission Path
1) Set the transmission frequency on the re-
ceiver (
☞
chapter 6 1 or 6 2) If the transmit-
ter is still switched off and the LED bar graph
RF (3) indicates reception, interference signals
or signals from another wireless transmit-
ter are received In this case, use a different
transmission frequency
2) Switch on the transmitter and set it to the
transmission frequency of the receiver (
☞
in-
structions of the transmitter) The LED bar
graph RF indicates the strength of the radio
signal
For detailed information on the display
indications refer to the overview in chapter 1
3) Speak / Sing into the microphone of the trans-
mitter or, when picking up the sound of an
instrument, feed audio signals to the micro-
phone Use the volume control (2) to match
the output level of the receiver to the input
of the subsequent unit
The LED bar graph AF (4) indicates the
volume level of the transmitter Adjust the
level on the transmitter, if necessary (
☞
in-
structions of the transmitter)
In case of no reception or poor reception, please
check the following items:
– Are the batteries of the transmitter dis-
charged? The receiver indicates the battery
status of the transmitter:
☞
chapter 1: Dis-
play
– Are there any objects interfering with recep-
tion in the transmission path?
Keep the transmitter and the receiver at a
minimum distance of 50 cm from any metal
objects or possible sources of interference
(e g electric motors, fluorescent lamps)
– Is it possible to improve the reception quality
by turning the receiving antennas?
– Is the transmission power of the transmitter
too low (
☞
instructions of the transmitter)
and /or the squelch too high (
☞
chapter 6 4)?
8 Specifications
Carrier frequency range: 506 – 542 MHz
Audio frequency range: 50 – 18 000 Hz
Output level
XLR, bal : 120 mV
(20 dB level attenua-
tion to be activated)
6 3 mm jack, unbal : 70 mV
THD: < 0 6 %
Dynamic range: > 105 dB
Interference
suppression: via pilot tone and
adjustable squelch
function
Power supply: via power supply
unit provided and
connected to
230 V / 50 Hz
Dimensions: 211 × 40 × 145 mm
Weight: 1 kg
Subject to technical modification
All rights reserved by MONACOR
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
be reproduced in any form or by any means for any commercial use.