General safety instructions

WARNING

Any working methods that might endanger safety must be avoided!

Non-observation of these installation and operating instructions and the safety instructions herein may

endanger persons as well as the environment and the JUDO reverse osmosis system itself!

The safety instructions do not take into account

Random happenings and events that may occur during installation, operating and maintenance,

Location related safety conditions for the observance of which the operator is responsible, even for contract

installation personnel.

WARNING

Unauthorised conversions and changes to the JUDO reverse osmosis system or tampering with device

components are forbidden for safety reasons!

Do not perform any changes, make any additions or carry out any conversions that could impair safety

without the manufacturer’s written approval! 

Never remove safety equipment or deactivate it by making changes to the JUDO JRSF reverse osmosis

system!

The safety instructions of these installation and operating instructions must be observed without fail!

Only operate the JUDO reverse osmosis system with the caps and covers of all device components

correctly closed!

Fault-free operation of the JUDO reverse osmosis system is only ensured if original spare parts and

components are used in the combination described in these installation and operating instructions,

otherwise there is a risk of malfunctioning or damage!

Only allow authorised technical personnel to carry out repairs!

All work on electrical system components must only be performed by qualified electricians certified

according to an approved national scheme!

The electrical system components must be checked regularly!

Loose connections must be tightened immediately and damaged device components immediately

replaced!

WARNING

In the event of faults, switch off water and electrical power supplies.

CAUTION

Keep device away from children.

ATTENTION

If the device will not be used for more than 24 hours, switch off the water and electrical power supplies.

NOTE

The installation and operating instructions must always be available at the place of use of the JUDO

reverse osmosis system and must be kept in a good, legible state!

Separate installation and operating instructions of system components or other devices and systems

must also be observed!

NOTE

All persons involved in installation, commissioning, operation, maintenance and servicing of the JUDO

reverse osmosis system must be appropriately qualified and trained and must have carefully read and

understood these installation and operating instructions and also any separate installation and operating

instructions for other devices and systems or system components!

8

Bioquell

®

-PURE

07/2021 • 1703434

Summary of Contents for Bioquell PURE

Page 1: ...ting instructions Translation of the original operating instructions Bioquell PURE JUDO reverse osmosis system Please transfer to the operator Read before installation and commissioning Keep for futur...

Page 2: ...Safety instructions for mechanical operations 9 2 6 Product safety 9 2 7 Duties of the operator 10 3 Product information 11 3 1 Scope of supply 11 3 1 1 Extended accessories are part of the scope of s...

Page 3: ...any queries please specify the model name order and manufacturing numbers that you can find on the type label of your JUDO device Every JUDO reverse osmosis system has been carefully checked prior to...

Page 4: ...tood these installation and operating instructions and also any separate installation and operating instructions for other devices and systems 1 2 Validity of the installation and operating instructio...

Page 5: ...sal 1 6 1 Transport CAUTION Transport the JUDO reverse osmosis system with care in an upright position do not knock over do not transport when there is a risk of frost also protect against dust and di...

Page 6: ...danger symbol Warning of electric voltage Table 2 Danger pictographs Mandatory pictographs Mandatory pictographs show actions that must be followed to prevent danger The following mandatory pictograph...

Page 7: ...a danger which if not avoided will result in death or severe injury WARNING Orange WARNING identifies a danger which if not avoided may result in death or severe injuries CAUTION Yellow CAUTION ident...

Page 8: ...inal spare parts and components are used in the combination described in these installation and operating instructions otherwise there is a risk of malfunctioning or damage Only allow authorised techn...

Page 9: ...ressurised NOTE These activities must only be performed by JUDO customer service or corresponding technical personnel who know and understand the overall system of the device and its environment 2 6 P...

Page 10: ...omplied with No conversions or changes to the product can be performed without the agreement of the manufacturer All conversions and changes must be checked and documented from a safety point of view...

Page 11: ...m receipt of goods and any hidden defects within 8 days from their detection Upon product delivery missing parts as well as missing technical documents or materials must also be reported within 8 days...

Page 12: ...3 Functional layout Fig 2 Functional layout 1 T valve water inlet 9 TDS measuring sensor outlet 2 TDS measuring sensor inlet 10 T33 activated carbon filter from coconut shells 3 PP activated carbon fi...

Page 13: ...The PP activated carbon filter removes dirt particles decomposition substances deposits sand and other parti cles to protect the RO membrane Stage 2 With a filtration fineness of 0 0001 m the reverse...

Page 14: ...nse 6 Leak sensor el connection LEAK SENSOR 18 PP activated carbon filter remaining capacity display 7 Power supply unit el connection POWER 19 Clean device display Purify 8 Opening audible signal out...

Page 15: ...bar 1 4 Water temperature C 4 30 Electrical data VAC 100 240 In Hz 50 60 Power supply via adapter Out VDC 24 Requirements for the installation site Temperature range C 4 40 Air humidity 90 Dimensions...

Page 16: ...NOTE Only designated for operation in closed spaces 4 1 Conditions for safe connection The device is equipped with a booster pump and many only be operated with clean drinking water Only operate using...

Page 17: ...tor con nected Pull off locking clip Pull back the mount ing ring and hold Pull the PE tube out of the push fit con nector 1 Locking clip blue 4 PE tube 2 Mounting ring 5 Gap for locking clip 3 PE tub...

Page 18: ...et for clean PURIFIED water Connect 1 4 push fit connectors on one side of the connections on the water tap Measure the distance between the connection at the water tap and the PURIFIED outlet Cut a 1...

Page 19: ...the water tap Close the lever for drinking water 4 4 1 Initial commissioning Upon first use open the water tap and the inlet valve If water now runs re close the water tap for 30 minutes During this t...

Page 20: ...nd an alarm tone sounds for six seconds Once the leak has been rectified the device can be restarted by plugging in the mains cable Fault If filtering or flushing continues for a period 20 minutes the...

Page 21: ...the service life of the cartridge has elapsed the cartridge must be replaced 5 2 Filter cartridge replacement NOTE To achieve an effective and efficient filtering of the water and a uniform high wate...

Page 22: ...has not been used for a long time Flush the filter cartridges for five min utes If there is no improvement replace filter cartridges Poor feed water quality Feed water quality check Water tastes bad...

Page 23: ...agents or highly volatile solvents such as thinners petrol or alcohol The use of these agents can result in cracking of the housing and discolouration Do not submerge device in water Only clean the d...

Page 24: ...seraufbereitung AG Switzerland subsidiary Industriestrasse 15 CH 4410 Liestal Tel 41 0 61 906 40 50 info judo online ch www judo online ch JUDO Wasseraufbereitung GmbH BeNeLux subsidiary Laarbeeklaan...

Reviews: