2. TECHNICAL SPECIFICATIONS
Parameters
Units of
measurement
ADI125
ADI150
ADX95
ADX125
ADX150
ADX187.5
ADX250
Dimensions:
mm
1250
1500
950
1250
1500
1875
2500
Length without side panels
Length with side panels
1310
1560
1035
1335
1585
1960
2585
Depth
900
900
800
800
800
800
800
Height
2085
2085
2000
2000
2000
2000
2000
Exposure area of one shelf
m
2
3,5
4,2
3,4
Refrigerated volume
l
1160
1390
800
1000
1250
1550
2000
Useful volume
l
930
1115
590
780
935
1170
1560
Weight of the cabinet
kg
370
290
Refrigerant
R404a R452a R404a R452a
R290
Amount of refrigerant
kg
0,9
0,9
0,98
0,98
0,15
CO2 EQ
t
3,56
1,93
3,84
2,10
0,00
0,00
0,00
0,00
0,00
Rated current
А
4,5
6,3
Power consumption
kWt/24h
11,5
12,3
Climate category
3
Recommended ambient temperature
°С
+16….+25
Operating temperature range
°С
+2…+8
Power supply voltage
V/ Hz
220-240/50
Cooling mode
dynamic
Defrost mode
automatic
Package:
pcs
shelves
feet/wheels
Maximum load per shelf
kg
40
50
20
Summary of Contents for ADI125