The showcase is equipped with a system of automatic defrosting of the evaporator - with an interval of 8 hours. In the case
of incomplete defrosting, this should be done manually (look point 4.3). The compressor is equipped with an internal backup
(thermal) switch, which protects the engine from accidental overloads. If you hear unnatural, loud operation or the heavy start
of the compressor, switch off the appliance, check the condition of the condenser (in case of pollution - clean it).
WARNING! Failure to perform this service can result in a complicated starting of the compressor, the operation
of the unit, the overheating of the compressor and, consequently, deterioration of the cooling efficiency.
The manufacturer is not responsible for damage to the unit that arose as a result of noncompliance with the
purity of the condenser!
5. FAULT IDENTIFICATION AND REPAIR
In case of any problems during the startup of the equipment or its operation, it is necessary to return to those sections of
the service manual that explain their operations. This aims to ensure that the device is properly operated. If you still experience
difficulties, the following hints will help you solve the problem.
The equipment does not work
Make sure that:
• The device is connected to an electrical power supply
• Voltage and frequency in the network corresponds to those recommended by the manufacturer 220 V / 50 Hz
• The main switch is turned on
• The controller is switched on
Water leakage under the device or into the chamber
Make sure that:
• Verify the correctness of device levelling
• Verify the patency of outlet hoses
• Empty the condensate tray or container