– 96 –
(2) Fixed refuge position setup
Irrespective of the second origin in the pattern data, a memory switch is available to set up the second origin
(fixed refuge position) that is common to each pattern.
When the use of the fixed refuge position has been set up with the memory switch K90, the fixed refuge position
becomes enabled, which has been set up with the fixed refuge position Coordinate X of Memory Switch K117
and the fixed refuge position Coordinate Y of Memory Switch K118. In this state, the feeding frame can be ready
in the same position even though any pattern is used for sewing.
1. Selection of the fixed refuge position
Using the memory switch K90, it is possible to set up the fixed refuge position.
Setup
Contents
Explanation
Fixed refuge position
The fixed refuge position is not used.
disabled
CP20: 0
Fixed refuge position
The fixed refuge position is used.
enabled
CP20: 1
2. Fixed refuge position coordinates setup
Using the memory switch K117, it is possible to set up the fixed refuge position Coordi-
nate X.
Setup
Contents
Explanation
Coordinate X Coordinate X of the
Coordinate X of the fixed refuge position is
fixed refuge position
set up within the feeding frame in the unit of
0.1mm.
Using the memory switch K118, it is possible to set up the fixed refuge position Coordi-
nate Y.
Setup
Contents
Explanation
Coordinate Y Coordinate Y of the
Coordinate Y of the fixed refuge position is
fixed refuge position
set up within the feeding frame in the unit of
0.1mm.
(Caution) Coordinate X is (+) when the needle position is right of the origin.
It is (-) when the needle position is left of the origin.
Coordinate Y is (+) when the needle position is behind the origin.
It is (-) when the needle position is in front of the origin.
Needle
position