– 103 –
Output No.
Contents
Explanation
70
Bobbin status
Bobbin key
→
Bobbin status
71
Main unit input status
Main unit input key
→
Main unit input status
72
Pattern check status
Pattern check, thread tension / intermediate presser height command setup
73
Last mode status
Last mode status (Sewing machine revolutions / output / XY / presser thread cutter / thread
clamp / intermediate presser test mode)
74
Presser SW input effective
When the presser switch input is effective
75
Start SW input effective
When the start switch input is effective
76
Temporary stop SW turned OFF Temporary stop switch error (E050) being displayed (E050). OFF by reset.
77
Thread breakage error OFF
Thread breakage error (E052) being displayed. OFF by reset.
78
Air pressure being lowered
Air pressure low error (E031) being displayed. OFF by reset.
79
Other errors being present
Errors other than 76 to 78 being displayed. OFF by reset.
80
Sewing counter carryover
Sewing counter carryover being displayed. OFF by counter reset.
81
Sheet counter carryover
Sheet counter carryover being displayed. OFF by counter reset.
For the trigger
97
READY operation start
When the READY key is accepted. ON for 100ms.
98
READY operation end
After moving to (READY key
→
) sewing start point. ON for 100ms.
99
Sewing start
When the Start switch is accepted. (Normal / Midway stop / Temporary stop). ON for 100ms.
100
Before sewing start point reset
Before sewing start point reset (after pattern data end). ON for 100ms. Origin reset not
included.
101
After sewing start point reset
After sewing start point reset (before feeding frame lifting). ON for 100ms. Origin reset in-
cluded.
102
Before sewing machine start
Before sewing machine head driving (before feeding frame lowering). ON for 100ms.
103
After sewing machine stop
After sewing machine head stop (after wiper and before feeding lifting). ON for 100ms.
104
Before jump feed start
Jump feed operation / Feed forward / Return operation. ON for 100ms.
105
Before origin reset start
When the origin reset key is accepted. ON for 100ms.
106
Before total presser lowering
At the time of total presser lowering (Ready, threading, bobbin, etc.). ON for 100ms.
107
Before total presser lifting
At the time of total presser lifting (Ready, threading, bobbin, etc.). ON for 100ms.