(3) Crank rod connection/disconnection
1. Loosen 3 set screws
and 2 set screws
. On this occasion, loosen No. 2 set screws first, and completely
disengage No. 1 set screws from the flat section of the oscillator shaft
.
2. Pull out the oscillator shaft
in the direction of Arrow A.
3. Remove the main shaft
according to “3.-(1) Main shaft connection/disconnection”, and remove the crank
rod unit
.
– 9 –
22.1 to 22.6mm
Face B
No. 2 set screw
No. 1 set screw
C
A
E
D
Procedures of disassembling
No. 1 set screw
No. 2 set screw