– 173 –
O
N
1
2
3
4
SW3
O
N
1
2
3
4
SW2
(2) Dipswitch setup
1. The penetration force is increased when “4” of
Dipswitch SW1
is turned ON on the SDC board
.
2. If the penetration force is insufficient for thick materi-
als, this switch should be turned ON.
3. All other dipswitches should be turned OFF.
(Caution) Dipswitch changeover should be done af-
ter the power supply has been turned off.
4. All dipswitches on the MAIN board are turned OFF.
SDC board
MAIN board
SW1 SW1