– 69 –
(2) Function list
Level 1 (Refer to the instruction manual for changing procedure.)
No.
Item
Setting range
Initial value
SS/HS SL/HL
SL/HL
SL/HL
SL/HL
1306
1306
1510
2206
2210
SS/HS
1306
FU05
SL/HL
1306
FU05
SL/HL
1510
FU05
SL/HL
2206
FU05
SL/HL
2210
FU05
1
Maximum sewing speed
200 to 2700rpm
100rpm
2700
2
Sewing speed of 1st stitch
200 to 1500rpm
100rpm
1500
In case of with thread clamp
3
Sewing speed of 2nd stitch
200 to 2700rpm
100rpm
2700
In case of with thread clamp
4
Sewing speed of 3rd stitch
200 to 2700rpm
100rpm
2700
In case of with thread clamp
5
Sewing speed of 4th stitch
200 to 2700rpm
100rpm
2700
In case of with thread clamp
6
Sewing speed of 5th stitch
200 to 2700rpm
100rpm
2700
In case of with thread clamp
7
Thread tension of 1st stitch
0 to 200
1
200
In case of with thread clamp
8
Thread tension setting at the time
0 to 200
1
0
of thread trimming
9
Thread tension changeover timing
–6 to 4
1 (4
°
)
0
at the time of thread trimming
10
Sewing speed of 1st stitch
200 to 1500rpm
100rpm
200
In case of without thread clamp
11
Sewing speed of 2nd stitch
200 to 2700rpm
100rpm
600
In case of without thread clamp
12
Sewing speed of 3rd stitch
200 to 2700rpm
100rpm
1000
In case of without thread clamp
13
Sewing speed of 4th stitch
200 too2700rpm
100rpm
1500
In case of without thread clamp
14
Sewing speed of 5th stitch
200 to 2700rpm
100rpm
2000
In case of without thread clamp
Smallest
change-
able unit