– 70 –
No.
Item
Setting range
Initial value
SS/HS SL/HL
SL/HL
SL/HL
SL/HL
1306
1306
1510
2206
2210
15
Thread tension of 1st stitch
0 to 200
1
0
In case of without thread clamp
16
Thread tension changeover timing
–5 to 2
1
–5
at the sewing start
In case of without thread clamp
0: Normal
17
Operation panel key lock mode
1: X enlarging/
–
0
(CP-20 only)
Y enlarging/speed-
Item skip
0: Sewing up
18
Counter motion selection
counter
–
0
(CP-20 only)
1: Bobbin thread
Down counter
19
Height of presser at the time of
50 to 90
1
70
2-step stroke
0: Without buzzer
sound
20
Buzzer sound can be prohibited
1: Panel operating
–
2
sound
2: Panel operating
sound + error
21
Number of stitches of thread clamp
1 to 7 (stitches)
1
2
release is set
22
Clamping timing of thread clamp can
–10 to 0
1 (4
°
)
0
be delayed
23
Thread clamp control can be
0: Normal
prohibited
–
0
1: Prohibition
Smallest
change-
able unit
SS/HS
1306
FU05
SL/HL
1306
FU05
SL/HL
1510
FU05
SL/HL
2206
FU05
SL/HL
2210
FU05