– 73 –
No.
Item
Setting range
Initial value
SS/HS SL/HL
SL/HL
SL/HL
SL/HL
1306
1306
1510
2206
2210
Thread clamp and thread clamp
0: Standard (front)
38
position selection
–
0
1: Rear
0: Disabled
39
Thread breakage detection selection
–
1
1: Enabled
40
Number of invalid stitches at the start
0 to 15 stitches
1
8
of sewing of thread breakage detection
41
Number of invalid stitches during
0 to 15stitches
1
3
sewing of thread breakage detection
(For motor-driven frame)
0: 1 step
1: 2-step stroke
(move downward to the
owest point with presser SW)
2: 2-step stroke
(start to move down-
ward to the lowest
point with start SW)
3: 2-step stroke (With
presser SW1: mid-point,
lowermost position,
rise)
4-99: 1 step
(For pneumatic frame)
0: Integrated type frame
42
Feeding frame control/pedal
1: Right-left separate
1
0
1
0
2
open-close
type frame, no preference
between right and left
2: Right-left separate
type frame, order: right
→
left
3: Right-left separate
type frame, order: left
→
right
4: Integrated type stroke
5: Right-left separate
type left stroke, no preference
between right and left
6: Right-left separate
type left stroke,
order: right
→
left
7: Right-left separate
type left stroke,
order: left
→
right
8-99: Integrated
type frame
Smallest
change-
able unit
SS/HS
1306
FU05
SL/HL
1306
FU05
SL/HL
1510
FU05
SL/HL
2206
FU05
SL/HL
2210
FU05