– 112 –
When polyethylene oler
1
becomes filled with oil,
remove polyethylene oler
1
and dran the ol.
1-9. Draining waste oil
1
1-11. Replacing the fuse
WARNING :
1. To avoid electrical shock hazards, turn OFF the power and open the control box cover after about
five minutes have passed.
2. Open the control box cover after turning OFF the power without fail. Then, replace with a new fuse
with the specified capacity.
The machne uses the followng three fuses :
1
For pulse motor power supply protecton
15A (tme-lag fuse)
2
For solenod and pulse motor power supply
protecton
3.15A (tme-lag fuse)
3
For control power supply protecton
2A (fast-blow type fuse)
1) Loosen setscrew
1
and remove setscrew
1
.
2) When screwng n adjustment screw
2
, the
amount of ol of ol ppe, left
4
can be reduced.
3) After the adjustment, screw n setscrew
1
and fix it.
1. The state of standard delivery is the po-
sition where
3
is lightly screwed in and
returned by 4 turns.
2. When reducing the amount of oil,
do not screw in the screw at once.
Observe the state for approximately
half a day at the position where
3
is
screwed in and returned by 2 turns.
If reducing is excessive, worn-out
of the hook will result.
1-10. Amount of oil supplied to the hook
1
1
2
4
3
2
3