– 99 –
When polyethylene oiler
1
becomes filled with oil,
remove polyethylene oiler
1
and drain the oil.
1-9. Draining waste oil
1
1-11. Replacing the fuse
WARNING :
1. To avoid electrical shock hazards, turn OFF the power and open the control box cover after about
five minutes have passed.
2. Open the control box cover after turning OFF the power without fail. Then, replace with a new fuse
with the specified capacity.
The machine uses the following three fuses :
1
For pulse motor power supply protection
15A (time-lag fuse)
2
For solenoid and pulse motor power supply
protection
3.15A (time-lag fuse)
3
For control power supply protection
2A (fast-blow type fuse)
1) Loosen setscrew
1
and remove setscrew
1
.
2) When screwing in adjustment screw
2
, the
amount of oil of oil pipe, left
4
can be reduced.
3) After the adjustment, screw in setscrew
1
and fix it.
1. The state of standard delivery is the
position where
3
is lightly screwed
in and returned by 1.5 turns.
2. When reducing the oil amount, do
not screw in the screw once. Ob-
serve the state for approximately
half a day and screw
3
. If reduc-
ing is excessive, worn-out of the
hook will result.
1-10. Amount of oil supplied to the hook
1
1
2
4
3
2
3